Toshiba VLP Technology Q9 Plus Installation & Operation Manual page 264

Asd
Table of Contents

Advertisement

LED
LCD
Screen
Screen
E-13
Over-Speed
OT
Over-Torque
Over-Voltage
OP1
Acc
Over-Voltage
OP2
Dec
Over-Voltage
OP3
Run
E-21
Stack Err
SOUT
Step-Out (PM)
OCA1
U-Phase OC
OCA2
V-Phase OC
OCA3
W-Phase OC
Note:
The event that caused the trip(s) must be corrected or must decrease to less than the threshold value
required to cause the trip to allow for a Reset to be recognized. In the event of multiple active trips, the
trip displayed will remain until all faults are corrected and cleared.
Q9 Plus ASD Installation and Operation Manual
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Table 19. Fault Codes (Continued)
Fault Description
Speed Error (Over-Speed).
Over-Torque.
Over-Voltage During
Acceleration.
Over-Voltage During
Deceleration.
Over-Voltage During Fixed
Speed Operation.
Stack Overflow Error.
Step-Out (For PM Motors
Only).
U-Phase Over-Current.
V-Phase Over-Current.
W-Phase Over-Current.
Possible Cause
• Result of a motor speed that is greater than the
commanded speed when using an encoder for
speed control.
• Improper encoder connection or setup
information.
• Defective encoder.
• Output torque requirement in excess of the
or
F617
settings for a time longer than the
setting.
• Motor is running during restart.
• Deceleration time is too short.
• Stall prevention is disabled.
• 3-phase input voltage is out of specification.
• Input reactance is required.
• Load fluctuations.
• 3-phase input voltage out of specification.
• Service call is required.
• Service call is required.
• Low impedance at the U/T1 phase.
• Low impedance at the V/T2 phase.
• Low impedance at the W/T3 phase.
F616
F618