Option Instruction Manual
CCL001Z1
NOTICE
E6581476②

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba TOSVERT VF-AS1

  • Page 1 E6581476② TOSVERT VF-AS1/PS1 Option Instruction Manual CCL001Z1 NOTICE 1. Make sure that this instruction manual is delivered to the end user of the CC-Link option for the VF-AS1/PS1. 2. Read this manual before installing or operating the CC-Link option unit, and store it in a safe place for reference.
  • Page 2 E6581476② Safety precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users and damages to assets and for proper use of the device. Read the instruction manual attached to the inverter along with this instruction manual for completely understand the safety precautions, the symbols and indications shown below.
  • Page 3 E6581476② ■ Handling in general Danger Never disassemble, modify or repair the product. ▼ Disassembling the product may cause electric shocks, fire or injuries. Disassembly prohibited For repairs, call your sales/repair agency. ▼ Do not attach this option to any inverter other than the VF-AS1/PS1. It may lead to electric shocks or fire.
  • Page 4 E6581476② ■ Wiring Danger ▼ Turn off input power before installing and wiring this option. Wait at least 15 minutes and check to make sure that the charge lamp (VF-AS1/PS1) is no longer lit. Mandatory ▼ Tighten the screws on the terminal block to the specified torque (Refer to Section 3.2). If the screws are not tightened to the specified torque, it may lead to fire.
  • Page 5 E6581476② Preface Thank you for purchasing a “CC-Link Option (CCL001Z1)” for TOSVERT VF-AS1/PS1 inverter. This option can connect with open field network CC-Link and data communications with the CC-Link master through installing this option in the VF-AS1/PS1 and using it. Besides this instruction manual, the "CC-Link option Function Manual"...
  • Page 6: Table Of Contents

    E6581476② - Table of contents - 1. Overview················································································································································· 6 2. Name of functions of main parts ············································································································ 6 2.1. Exterior features···························································································································· 6 2.2. Set the station No. and baud rate ································································································· 7 2.3. About indicator of LED ·················································································································· 7 2.4. CC-Link connector ························································································································ 8 3.
  • Page 7: Overview

    E6581476② 1. Overview This option allows the VF-AS1/PS1 inverter to be connected into a CC-Link network. CC-Link supports a maximum of 42 nodes, allowing for the Master unit and this option is based on CC-Link Ver.1.10. The CCL001Z1 is able to operate RUN/STOP, monitor the status of the inverter, set the inverter's parameter and etc.
  • Page 8: Set The Station No. And Baud Rate

    E6581476② 2.2. Set the station No. and baud rate For the setting station number or communication speed to take effect, power needs to be turned off and then turned back on. x10 (SW2) x1 (SW3) BAUD RATE (SW1) Rotary switch for the Rotary switches for the setting up a baud rate setting up a station No.
  • Page 9: Cc-Link Connector

    E6581476② Behavior of LED State of LED Cause L.RUN L.ERR Normal communication is made but CRC error has occurred     due to noise. Normal communication     Hardware fault     Hardware fault ...
  • Page 10: Installing The Ccl001Z1

    E6581476② 3. Installing the CCL001Z1 Turn off input power of VF-AS1/PS1 and wait for at least 15 minutes and then check Mandatory that the CHARGE lamp on VF-AS1/PS1 is no longer lit. Install the CC-Link option to VF-AS1/PS1 as follows. *1 When this option is used together with the I/O card option, attach this option to the front panel side.
  • Page 11 E6581476② (B) For VFAS1/VFPS1 200V 55kW or more, 400V 90kW or more a) Insert a flat-blade screwdriver in each of the two holes at the upper part of the front panel, release the panel mounting tab by pushing the screwdriver down, and remove the front panel cover.
  • Page 12: Case Of Installing Two Options

    E6581476② LED name label POWER L.RUN L.ERR 3.1. Case of installing two options Please install this option (CCL001Z1) on the top of options when you install two options. Do not install under the another option. 3.2. Connection of CC-Link cable If use other than the CC-Link dedicated cable, the performance of the CC-Link system is not guaranteed.
  • Page 13: Wiring / Connection With The Cc-Link Master

    E6581476② 3.4. Wiring / Connection with the CC-Link master The example of wiring/connection with the CC-Link master unit is shown in the following figure. Motor R/L1 U/T1 Inverter S/L2 V/T2 T/L3 VF-AS1/PS1 W/T3 CC-Link   CCL001Z Master Unit ※1 The example of wiring with the inverter VF-AS1/PS1 As for master station, when use the Mitsubishi Electric An series, the recommended version is "LS"...
  • Page 14: Functions

    E6581476② * Maximum number of units connected to one master station is 42 units (when only inverters are connected). * If any other units are included, the number of occupied stations depends on the unit. So the connectable number of units is different. 4.
  • Page 15: Basic Functions

    E6581476② 4.2. Basic functions This clause shows the basic function of this CC-Link option using by CC-Link communication. 4.2.1. Run and frequency operation command The PLC program can operate the inverter to run, stop, set the operation frequency and change the parameters. If the PLC controls these operations, select the command mode and the frequency setting mode.
  • Page 16: Unusual Diagnosis

    E6581476② 5. Unusual diagnosis The VF-AS1/PS1 is able to install two kind options. The option error message is depended on the position of the option under or panel side. 5.1. Option error The error message is displayed when there is hardware error, software error or lose of connection of wire.
  • Page 17: List Of Cc-Link Data

    E6581476② 6. List of CC-Link data This option occupies one station area of the buffer memory of the PLC. 6.1. RX(Monitor), RY(Instruction) List of remote I/O Inverter (Slave) PLC (Master) PLC (Master) Inverter (Slave) -> -> Device No. Signal Device No. Signal RXn0 Forward running...
  • Page 18: Rwr, Rww Resister

    E6581476② 6.2. RWr, RWw resister RWr . RWw (Default value = 0) Inverter → PLC (RWr) PLC → Inverter (RWw) Address Contents Address Contents RWr n First monitor value RWw n Monitor code (first and second) RWr n+1 Second monitor value (output frequency) RWw n+1 Set frequency/ torque RWr n+2 Reply code RWw n+2 Instruction code...
  • Page 19 E6581476② Second Monitor Description First Monitor Description Code Number Unit (the higher 8 bits) (the lower 8 bits) My function monitor 1 My function monitor 1 - My function monitor 2 My function monitor 2 - My function monitor 3 My function monitor 3 -...
  • Page 20: Instruction Codes

    E6581476② 6.4. Instruction Codes Code No. Contents Description 0 : Terminal input enabled Command mode selection read 1003H 1 : Operation panel input enabled (including LED/LCD option input) 2 : 2-wire RS485 communication input Command mode selection write 2003H 3 : 4-wire RS485 communication input 4 : Communication option input VI/II (voltage/current input) RR/S4 (potentiometer/voltage input)
  • Page 21: Reply Code

    E6581476② 6.5. Reply Code Reply code Data Item Detailed contents 0000H Normal (No error) Normal completion of instruction code execution Execution error. 0001H Write error (Write protected during operation) 0002H Parameter selection error Unregistered code number was set. 0003H Setting range error Set data is outside the setting data range.
  • Page 22: Specifications

    4) Damage due to the use of CC-Link communication option for non-intended purposes. 4. Unless a service contract is signed beforehand between the customer and Toshiba, in witch case the service contract has priority over this warranty. - 21 -...