F288
Preset Speed 9
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1001 and is
identified as Preset Speed 9. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed.
See
F018
for additional information on this parameter.
Preset Speed 10
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1010 and is
identified as Preset Speed 10. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed.
See
F018
for additional information on this parameter.
Preset Speed 11
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1011 and is
identified as Preset Speed 11. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed.
See
F018
for additional information on this parameter.
Preset Speed 12
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1100 and is
identified as Preset Speed 12. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed.
See
F018
for additional information on this parameter.
Preset Speed 13
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1101 and is
identified as Preset Speed 13. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed.
See
F018
for additional information on this parameter.
Preset Speed 14
Program Frequency Preset Speeds
This parameter assigns an output frequency to binary number 1110 and is
identified as Preset Speed 14. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed.
See
F018
for additional information on this parameter.
Q9 Plus ASD Installation and Operation Manual
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Direct Access Number — F288
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower-Limit Freq. (F013)
Maximum — Upper-Limit Freq. (F012)
Units — Hz
Direct Access Number — F289
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower-Limit Freq. (F013)
Maximum — Upper-Limit Freq. (F012)
Units — Hz
Direct Access Number — F290
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower-Limit Freq. (F013)
Maximum — Upper-Limit Freq. (F012)
Units — Hz
Direct Access Number — F291
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower-Limit Freq. (F013)
Maximum — Upper-Limit Freq. (F012)
Units — Hz
Direct Access Number — F292
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower-Limit Freq. (F013)
Maximum — Upper-Limit Freq. (F012)
Units — Hz
Direct Access Number — F293
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower-Limit Freq. (F013)
Maximum — Upper-Limit Freq. (F012)
Units — Hz
F293