Table B-5: For Divisions:
Temperature class /
Maximum surface
temperature
Division Dust groups:
T3
T4
T5
T6
Table B-6: For Zones:
Temperature class /
Maximum surface
temperature
Zone Gas groups:
T2
T3
T4
Zone Dust groups:
T250°C
T200°C
T135°C
T100°C
T85°C
B.9

Canada

B.9.1
E6 Explosionproof, Dust-Ignitionproof
Certificate FM-C FM16CA0011X
Standards C22.2 NO. 0.4-17:2017, C22.2 NO. 0.5-16:2016, C22.2 No. 25-17:2017,
Markings
Rosemount 5408 Level Transmitter
(continued)
Ambient temperature range
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
Ambient temperature range
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
-55 °C ≤ Ta ≤ 70 °C
C22.2 No.30-M1986:1986 (R:2016), C22.2 No.94-M91:1991 (R:2011),
C22.2 No. 61010-1:2004, CAN/CSA C22.2 No. 60079-0:2015 Ed. 3, C22.2
No. 60079-1:2016 Ed. 3, C22.2 No. 60079-26:2016; CAN/CSA-C22.2 No.
60079-31:2015, C22.2. 60529:2016, ANSI/ISA 12.27.01:2011
XP CL I, DIV 1, GRPS A-D T6...T2
DIP CLII/III, DIV 1, GRPS E-G; T6...T3
Ex db IIC T6...T3 Gb
Ex tb IIIC T85°C...T250°C Db
Product Certifications
June 2019
Process temperature range
-55 °C to 160 °C
-55 °C to 130 °C
-55 °C to 95 °C
-55 °C to 80 °C
Process temperature range
-55 °C to 250 °C
-55 °C to 195 °C
-55 °C to 130 °C
-55 °C to 250 °C
-55 °C to 195 °C
-55 °C to 130 °C
-55 °C to 95 °C
-55 °C to 80 °C