Canada; Europe; International - Emerson Rosemount 705 Reference Manual

Wireless totalizing transmitter
Hide thumbs Also See for Rosemount 705:
Table of Contents

Advertisement

Reference Manual
00809-0200-4705, Rev AB
Special Conditions for Safe Use (X):
1. For use only with the Model 701P or Rosemount P/N
753-9220-XXXX Smart Power Battery Module.
2. The surface resistivity of the antenna is greater than 1GΩ. To
avoid electrostatic charge build-up, it must not be rubbed or
cleaned with solvents or a dry cloth.
B.7 Canada
I6
Canada Intrinsically Safe (IS)
Certificate: CSA 70011131
Standards: CAN/CSA C22.2 No. 0-10,
CAN/CSA C22.2 No. 94-M91,
CSA Std C22.2 No.142-M1987,
CAN/CSA-60079-0 - 2011,
CAN/CSA-60079-11 - 2014,
CSA Std C22.2 No. 60529 - 2005,
CAN/CSA-C22.2 No. 61010-1 - 2012
Markings: IS CL I, DIV 1, GP A, B, C, D T4;
Ex ia IIC T4 Ga, T4; T4 (–50 °C ≤ T
when installed per Rosemount drawing
00705-1020; Type 4X; IP66
See the table at the end of this section for entity parameters.
N6 Canada Division 2, Nonincendive
Certificate: CSA 70011131
Standards: CAN/CSA C22.2 No. 0-10,
CAN/CSA C22.2 No. 94-M91,
CSA Std C22.2 No. 213-M1987 (R2013),
CAN/CSA-60079-0 - 2011,
CAN/CSA Std C22.2 No. 60529 - 2005,
CAN/CSA-C22.2 No. 61010-1 - 2012
Markings: Suitable for Class 1, Division 2,
Groups A, B, C, D T4; T4 (–50 °C ≤ T
Type 4X; IP66
Special Conditions for Safe Use (X):
1. For use only with the Model 701P or Rosemount P/N
753-9220-XXXX Smart Power Battery Module.
2. The surface resistivity of the antenna is greater than 1GΩ. To
avoid electrostatic charge build-up, it must not be rubbed or
cleaned with solvents or a dry cloth.
B.8 Europe
I1
ATEX Intrinsic Safety
Certificate: Baseefa14ATEX0375X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
II 1 G Ex ia IIC T4 Ga, T4(–60 °C ≤ T
Markings:
For use with Rosemount SmartPower
number 753-9220-0001, or for use with Emerson
SmartPower option 701PBKKF.
See the table at the end of this section for entity parameters.
50
≤ +70 °C)
a
≤ +70 °C);
a
≤ +70 °C)
a
power module part
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1GΩ. To
avoid electrostatic charge build-up, it must not be rubbed or
cleaned with solvents or a dry cloth.
2. The Rosemount 705 Transmitter enclosure may be made of
aluminum alloy and given a protective polyurethane paint
finish; however, care should be taken to protect it from
impact or abrasion if located in a Zone 0 area.
IU
ATEX Intrinsic Safety for Zone 2
Certificate: Baseefa14ATEX0375X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
II 3 G Ex ic IIC T4 Gc, T4(–60 °C ≤ T
Markings:
+70 °C)
For use with Rosemount SmartPower Power Module part
number 753-9220-0001, or for use with Emerson
SmartPower option 701PBKKF.
See the table at the end of this section for entity parameters.
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1GΩ. To
avoid electrostatic charge build-up, it must not be rubbed or
cleaned with solvents or a dry cloth.
2. The Model 701PBKKF Power Module may be replaced in a
hazardous area. The Power Modules have a surface resistivity
greater than 1GΩ and must be properly installed I the
wireless device enclosure. Care must be taken during
transportation to and from the point of installation to
prevent electrostatic charge build-up.
3. The Rosemount 705 Transmitter enclosure may be made of
aluminum alloy and given a protective polyurethane paint
finish; however, care should be taken to protect it from
impact or abrasion if located in a Zone 0 area.
B.9 International
I7
IECEx Intrinsic Safety
Certificate: IECEx BAS 14.0173X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia IIC T4 Ga, T4 (-60 °C ≤ T
For use with Rosemount SmartPower power module part
number 753-9220-0001, or for use with Emerson
SmartPower option 701PBKKF.
See the table at the end of this section for entity parameters.
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than
1 GΩ. To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or a dry cloth.
2. The Rosemount 705 Transmitter enclosure may be made of
aluminum alloy and given a protective polyurethane paint
finish; however, care should be taken to protect it from
impact or abrasion if located in a Zone 0 area.
Product Certifications
May 2017
a
≤ +70 °C)
a
Product Certifications

Advertisement

Table of Contents
loading

Table of Contents