Canada - Emerson Rosemount 5402 Reference Manual

Level transmitter, two-wire non-contacting radar
Hide thumbs Also See for Rosemount 5402:
Table of Contents

Advertisement

Product Certifications
October 2018
IE
FISCO
Certificate: FM16US0444X
Standards: FM Class 3600 – 2011; FM Class 3610 –
2010;
FM Class 3611 – 2004; FM Class 3615 – 2006;
FM Class 3810 – 2005; ANSI/ISA 60079-0 –
2013; ANSI/ISA 60079-11 – 2012;
ANSI/NEMA 250 – 2003;
Markings: IS CL I, II, III, DIV 1, GP A, B, C, D, E, F, G in
accordance with control drawing
9150079-905;
IS (Entity) CL I, Zone 0, AEx ia IIC T4 in
accordance with control drawing
9150079-905, NI CL I, II,
DIV 2, GP A, B, C, D, F, G;
Suitable for use in CL III DIV 2, indoor and
outdoor, T4 Ta=60 °C and 70°C; Type 4X
Specific Conditions for Safe Use (X):
1. WARNING - Potential Electrostatic Charging Hazard –
The enclosure contains non-metallic material. To
prevent the risk for electrostatic sparking, the plastic
surface should only be cleaned with a damp cloth.
2. WARNING - The apparatus enclosure contains
aluminum and is considered to constitute a potential
risk of ignition by impact or friction. Care must be
taken into account during installation and use to
prevent impact or friction.
U
i
17.5 V
FISCO parameters
B.6 Canada
E6 Explosion-proof, Dust- ignition-proof
Certificate: 1514653
Standards: CSA C22.2 No.0-M91, CSA C22.2
No.25-1966, CSA C22.2 No.30-M1986, CSA
C22.2 No.94-M91, CSA C22.2
No.142-M1987, CSA C22.2 157-92,
CAN/CSA C22.2 No. 60529:05,
ANSI/ISA 12.27.01-2003
Markings: Explosion-proof CL I, DIV 1, GP B, C, D; Dust-
ignition-proof CL II, DIV 1 and 2, GP E, F, G and
coal dust, CL III, DIV 1, Type 4X/IP66/IP67
I6
Intrinsically Safe and Non-Incendive Systems
Certificate: 1514653
243
I
P
C
i
i
i
380 mA 5.32 W
0
Standards: CSA C22.2 No.0-M91, CSA C22.2
No.25-1966, CSA C22.2 No.30-M1986, CSA
C22.2 No.94-M91, CSA C22.2
No.142-M1987, CSA C22.2 157-92,
CAN/CSA C22.2 No. 60529:05,
ANSI/ISA 12.27.01-2003
Markings: CL I, DIV 1, GP A, B, C, D, T4 see installation
drawing 9150079-906; Non-Incendive Class
III, DIV 1, Haz-loc CL I DIV 2, GP A, B, C, D,
Maximum Ambient Temperature +60°C for
Fieldbus and FISCO, and +70 °C for HART, T4,
Type 4X/IP66/IP67, Maximum Working
Pressure 5000 psi, Dual Seal.
Entity parameters
HART
Entity parameters
Fieldbus
IF
FISCO
Certificate: 1514653
Standards: CSA C22.2 No.0-M91, CSA C22.2
No.25-1966, CSA C22.2 No.30-M1986, CSA
C22.2 No.94-M91, CSA C22.2
No.142-M1987, CSA C22.2 157-92,
CAN/CSA C22.2 No. 60529:05,
ANSI/ISA 12.27.01-2003
Markings: CL I, DIV 1, GP A, B, C, D, T4 see installation
drawing 9150079-906; Non-Incendive Class
L
i
III, DIV 1, Haz-loc CL I DIV 2, GP A, B, C, D,
0
Maximum Ambient Temperature +60°C for
Fieldbus and FISCO, and +70 °C for HART, T4,
Type 4X/IP66/IP67,
Maximum Working Pressure 5000 psi, Dual
Seal.
FISCO parameters
Reference Manual
00809-0100-4026, Rev KC
U
I
P
i
i
i
30 V
130 mA
1 W
30 V
300 mA
1.3 W
U
I
P
i
i
i
17.5 V
380 mA 5.32 W
Product Certifications
C
L
i
i
7.26 nF
0
0
0
C
L
i
i
0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5401Rosemount 5400

Table of Contents