Usa; Canada - Emerson Rosemount 5600 Series Reference Manual

Level transmitter non-contacting radar with hart protocol
Hide thumbs Also See for Rosemount 5600 Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4024, Rev CA
B.5 USA
E5
Explosion-proof (XP), Dust-Ignitionproof (DIP)
5600 Series Transmitter
Certificate: FM 18US0053X
Standards: Class 3600 – 2011; Class 3610 – 2010;
Class 3615 – 2006; Class 3810 – 2005;
ANSI/NEMA 250 – 1991
Markings: Explosion-proof for use in Class I, Division 1, Groups
A, B, C and D, T6; Dust-Ignition-proof for use in
Class II, III, Division 1, Groups E, F and G, T5;
Ta= +70 °C; Type 4X
Explosion-proof for use in Class I, Division 1, Groups
A, B, C and D with Intrinsically Safe Connections to
Class I, Division 1, Groups A, B, C and D, T6;
Dust-Ignition-proof for use in Class II, III, Division 1,
Groups E, F and G, T5, Ta=+70 °C; Type 4X; in
accordance with Entity requirements and system
control drawing 9150074-994
Specific Conditions for Safe Use (X):
1. Warning – Potential Electrostatic Charging Hazard – The
enclosure is constructed from non-metallic material. To
prevent the risk of electrostatic sparking the plastic surface
should only be cleaned with a damp cloth.
2. Warning – The apparatus enclosure contains aluminum and
is considered to constitute a potential risk of ignition by
impact or friction. Care must be taken into account during
installation and use to prevent impact or friction.
2210 Display Unit
Certificate: FM16US0222X
Standards: Class 3600 – 2018; Class 3610 – 2018;
Class 3810 – 2018 ; ANSI/ISA 60079-0:2009 ;
ANSI/ISA 60079-11:2011 ;
ANSI/ISA 61010-1:2012 ; NEMA 250:2008 ;
ANSI/IEC 60529:2004
Markings: IS / I / 1 / ABCD / T4 Ta = 70°C — 9150074-997;
Entity; Type 4X; IP66, IP67
Specific Conditions for Safe Use (X):
1. WARNING – Potential Electrostatic Charging Hazard – The
enclosure is constructed from plastic. To prevent the risk of
electrostatic sparking the plastic surface should only be
cleaned with a damp cloth.
2. WARNING – The apparatus enclosure contains aluminum and
is considered to constitute a potential risk of ignition by
impact or friction. Care must be taken into account during
installation and use to prevent impact or friction.
3. To maintain ingress protection ratings IP66, IP67, the Type
4X rating and Class II, III ratings, thread sealant is required for
cable entries and blanking plugs.
Product Certifications
V
I
max
Input
Entity
Parameters
12 V
400 mA
Connector
X12
* Ci = 22 nF with an associated apparatus V
Ci = 15.7 μF with an associated apparatus V
V
I
oc
sc
Output
Entity
5.88 V
172.4 mA
Parameters
Connector
X17, X18
B.6 Canada
E6
Explosion-proof (XP)
5600 Series Transmitter
Certificate: 1346169
Standards: CSA C22.2 No 0-10 2010(R2015),
CAN/CSA C22.2 No 60079-0:2015,
CAN/CSA C22.2 No 60079-1:2016,
CAN/CSA C22.2 No 60079-7:2016 and
CAN/CSA C22.2 No 60079-11:2014,
CSA C22.2 No.142-M1987
Markings: Ex db eb IIC T6 Gb
TankRadar Pro Transmitter Head and 5600 Series
Radar Level Transmitter, Type TH43, rated 24-240
Vac, 10W up to two inputs 7 - 30V, 4 - 20mA;
up to two outputs 4 - 20mA, 300 Ohm max. or
Digital outputs TRL2bus, Profibus DP; ambient
temperature range [- 40C, + 70C]; for installation
refer to drawing # 9150074-937
Ex db eb [ib/ia] IIC T6 Gb
TankRadar Pro Transmitter Head and 5600 Series
Radar Level Transmitter, Type TH43, rated 24 -
240Vac, 10W; Intrinsically Safe Display Output(ia)
with entity parameters Uo=7.84V, Io=385.6mA,
Po=0.678W, Lo=0.17mH, Co=8.8μF; up to two
Intrinsically Safe Inputs(ib) with entity parameters
Ui=30V, Ii=200mA, Pi=1.3W, Li=0mH, Ci=0μF; up
to two Intrinsically Safe outputs(ib) with entity
parameters Uo=23.1V, Io=125.7mA, Po=0.726W,
Lo=2.2mH, Co=0.14. Or Digital outputs TRL2bus,
Profibus DP; ambient temperature range
[-40°C to +70°C]; for installation refer to drawing
#9150074-939.
Product Certifications
March 2020
P
C
max
max
i
n
0.7 W
22
F*
of 6.5 V or greater
oc
of less than 6.5 V
oc
P
C
L
o
a
a
μ
0.253 W 43
F 0.7 mH
L
i
0 mH
L
/R
o
o
140
μ
H/
110