5.1.4

Partial arming with keypad

To partially arm the system, follow the instructions below:
1. Enter on the keypad the Master code or a valid User code.
2. Press ON* key.
3. On the display appears an empty square for each existing and not active zone, associated
to the keypad and to the code. Black squares, if present, indicate that the zone is already
activated. In order to exit without arming press ESC key.
4. While the keypad buzzer rings, enter on the keypad the number of zones to be activated:
the respective squares become black.
5. Press again ON* key; the state LED starts blinking and the selected zones are activated.
6. The display automatically turns back to the standard screen after one minute.
In order to obtain in advance the standard screen, press ESC key.
Warning: if, instead of the empty square, "O" appears, it means that at least one open input is present in that
zone. See, in detail, which is the input through menu item «OPEN INPUTS» and either close back or exclude
that input
5.1.5

Partial arming with electronic or proximity key

To partially arm the system, with electronic key, follow the instructions below:
1.
Insert the electronic key in the reader; After a few seconds the reader will show the available partitioning sets
starting from the last performed one.
2.
To confirm selection, take out the key: armed zone LEDs will stay on with fixed light.
To partially arm the system, with proximity key, follow the instructions below:
1.
Approach the proximity key to the proximity reader transponder and keep it in this position for 3 seconds at
least.
2.
Move it away when the green LEDs will start blinking.
After a few seconds the reader will show the available partitioning sets starting from the last performed one.
3.
To confirm selection, approach the proximity key: armed zone LEDs will stay on with fixed light.
Warning: if yellow LED on the reader is blinking, it means that, in the system, at least one open input is present.
Before arming, identify the input and re-close or exclude it.
NOTE: If you use a key is not acquired (key not recognized), the green LEDs blink rapidly.
5.1.6

Partial arm by remote control

Partial arm of certain system zones can be only performed if the remote control has been properly programmed
(see § 4.11 Remote control programming).
To arm zones assigned to the remote control proceed as follows:
1.
Press Key 1
Arm remote control, if the control panel has acknowledged the command, the remote control
buzzer will sound a beep.
2.
On the keypad, the green LED "N " will start blinking thereby confirming partial system arming.
3.
On all reader, the green LEDs corresponding to armed zones will switch on.
Note: certain zones assigned to the remote control can be armed / disarmed using Key 3
into account the operating mode of this key:
A.
Pressing this key will switch system status from: disarmed to armed and vice versa (Toggle).
B.
Should zones assigned to the remote control be partially armed (partial arm), pressing this key will align all
zones to "arm" mode: zones that were not armed will be armed.
C. Once having set all zones assigned to the remote control in the arm condition, pressing again key 3, will cause
all zones disarming.
NOTE: function available with 1067 control panel and 1067/021 keypads, software version 3.00 or higher and with an
1067/010 radio expansion.