System Management; Arming; Total Arming With Keypad; Total Arming With Electronic Or Proximity Key - urmet domus 1067/032 Programming Manual

Bus control panel 8/32 inputs
Table of Contents

Advertisement

5

SYSTEM MANAGEMENT

5.1

ARMING

Two configurations are available: complete system arm and partial system arm.
Arm with keypad is the most configurable, while arms with electronic or proximity key are the easiest and the most
immediate.
If during arm there are open inputs, the system operates according to its configuration (Standard type zone,
Autoexclusion or System Arm lock).
5.1.1

Total arming with keypad

To totally arm the system follow the instructions below:
1. Enter on the keypad the Master code or a valid User code.
2. Press ON* key.
3. On the display appears an empty square for every existing and not active zone, associated to
keypad and code. Black squares, where present, indicate that the zone is already activated.
The buzzer signals that arm is in progress. To exit without arming press ESC key.
4. After 5 seconds the state LED turns on (steady if all the zones are activated, blinking if
some zones have not been activated) and the squares become black, indicating the
activated zones. If it is needed to speed up the procedure, press again ON* key and the
arm will be immediate.
5. The display automatically turns back to the standard screen after one minute. In order to
obtain in advance the standard screen, press ESC key.
Warning: , instead of the empty square, "O" appears, it means that at least one open input is present in that zone.
See, in detail, which is the input through menu item «OPEN INPUTS» and either close back or exclude that input.
Warning: by this procedure a user activates only the zones for which he is enabled, and not necessarily all the
zones.
5.1.2

Total arming with electronic or proximity key

To activate some zones with a reader, follow the instructions below:
1. Insert the electronic key in the reader, or bring near the proximity key to the proximity reader transponder
2. Remove the key or move the transponder away when the red LED "E" is blinking.
The 3 green LED indicate the status of the controlled zones: LED ON corresponds to zone armed.
If a LED has several assigned zones, this LED will blink if all these zones are not armed.
NOTE: The single zone arming capability depends on the key-reader settings and the utilized key.
From software release 2.00, several zones can be assigned to a each reader, up to covering all system zones (6 zones);
as a consequence several zones can be assigned to each green reader LED, up to covering the whole system.
5.1.3

Total arm by remote control

Total arm of all system zones can be only performed if the remote control has been properly programmed
(see § 4.11 Remote control programming).
To arm all zones (the whole system) via remote control, proceed as follows:
1.
Press Key 1
Arm remote control, if the control panel has acknowledged the command, the remote control
buzzer will sound a beep.
2.
On the keypad, the green LED "N " corresponding to total arm will switch on.
3.
On all readers, the green LEDs corresponding to all zones armed will switch on.
Note: the system can be armed /disarmed using Key 3
this key:
A.
Pressing this key will switch system status from: disarmed to armed and vice versa (Toggle).
B.
Should the system be armed partially (partial arm), pressing this key will align the system in "global arm":
system not armed zones will be armed.
C. Once having resumed the Total arming condition of all zones, pressing again key 3, will cause the Total
disarming of the system.
NOTE: function available with 1067 control panel and 1067/021 keypads, software version 3.00 or higher and with an
1067/010 radio expansion.
DS1067-035A
Toggle, however, take into account the operating mode of
69
ARM
□□□□..
EXECUTED
■■■■..
LBT8633

Advertisement

Table of Contents
loading

This manual is also suitable for:

1067/042

Table of Contents