3.1.5

Panic alarm

It is an alarm which can be triggered by a user in a situation of danger. It is always (24H) active and is temporarily
disabled by putting the system to maintenance status.
generated if...
The alarm is generated regardless of the zones status (24h).
activates...
is stored...
is displayed...
is held...
is stopped by...
3.1.6

Silent panic alarm

It is an alarm which can be triggered by a user in situations of danger and must not draw wrongdoer's attention. It is
always (24H) active and is temporarily disabled by putting the system to maintenance status.
generated if...
The alarm is generated regardless of the zones status (24h).
activates...
is stored...
is held...
is stopped by...
3.1.7

Hold-up alarm

It is an alarm which can be triggered by a user when he/she is forced by a wrongdoer to deactivate the system. It is
always (24H) active and is temporarily disabled by putting the system to maintenance status.
generated if...
The alarm is generated regardless of the zones status (24h).
activates...
is stored...
is held...
is stopped by...
DS1067-035A
a Panic input is opened
the remote control function key " + " (if programmed) is pressed for 5 seconds at least
the outputs programmed as Panic that have at least one zone shared with the input that
generated the event
the communicator for voice, modem or numerical sending of the respective Panic alarm
message (if programmed)
in the event log
in alarm volatile memory
on the keypads which have at least one zone shared with the input
on the readers which have at least one zone shared with the input
for burglar/tamper/panic alarm time
entering of a valid code in the keypad
insertion of a valid key
a zones disarm command given by a key input
a DTMF disarm command entered with a phone call to the control panel
disarm command from remote control having at least one shared zone with the input which
has generated the event.
a Silent panic input is opened
function key Silent panic on keypad is kept pressed for at least 3 seconds
the remote control function key "+" (if programmed) is pressed for 5 seconds at least
the outputs programmed as Silent panic that have at least one zone shared with the input
that generated the event or with the keypad where the dedicated key has been pressed
the communicator for voice, modem or numerical sending of the respective silent panic alarm
message (if programmed)
in the event log
for burglar/tamper/panic alarm time
entering of a valid code in the keypad
insertion of a valid key
a zones disarm command given by a key input
a DTMF disarm command entered with a phone call to the control panel
disarm command from remote control having at least one shared zone with the input which
has generated the event.
an hold-up input is opened
an hold-up code is entered with the keypad (code + 1)
the outputs programmed as Hold-up that have at least one zone shared with the input or the
keypad.
the communicator for voice, modem or numerical sending of the respective Hold-up alarm
message (if programmed)
in the event log
for a fixed time of 30 seconds
entering of a valid code in the keypad
insertion of a valid key
a zones disarm command given by a key input
a DTMF disarm command entered with a phone call to the control panel
disarm command from remote control having at least one shared zone with the input which
has generated the event.
13