4.20 SYSTEM TEST

When installation and configuration of system devices is finished, it is necessary to verify that the system is working
properly.
4.20.1

Inputs test

To verify if inputs are working properly follow the instructions below:
1. Enter on the keypad the Master code (default 111111) or the Installer code (default
000000) and press OK key.
2. Press MENU key.
3. Press ▼ key until "TEST" appears on the display.
4. Press OK key to confirm.
5. "INPUTS TEST IN PROGRESS..." appears. Press OK key to confirm.
6. Prompt all system detectors (for example, walk in front of volumetric detectors and open
the doors with magnetic contacts). Every time a detector is activated, on the keypad the
inputs LED turns on.
7. At the end press OK key to display the test result. Two different lists are available: the first
list, i.e. "TEST OK INPUTS", signals all those inputs which were prompted during the test,
while the second list, i.e. "TEST KO INPUTS", signals those inputs which were subjected to
variations. If all inputs opened regularly, no input must be present in the second list.
8. At the end press ESC key repeatedly to exit from the menu.
4.20.2

Outputs test

To verify if outputs are working properly follow the instructions below:
1. Enter on the keypad the Master code (default 111111) or the Installer code (default
000000) and press OK key.
2. Press MENU key.
3. Press ▼ key until "TEST" appears on the display.
4. Press OK key to confirm.
5. Press ▼ key until "TEST OUTPUT" appears.
6. Press OK key. "CONTROL PANEL" appears.
7. Confirm with OK key. The outputs list appears.
8. Select with ▲ and ▼ keys an output and press OK key. Press again OK to activate the
output; after verifying that the output is working properly, press OK key to deactivate it.
9. Follow the same procedure from step 7 for all the outputs.
10. If there are 1067/008 expansions, follow the same procedure from step 6 by selecting
every time a different bus device, whose outputs must be controlled.
11. After controlling all the outputs of all devices, press ESC key repeatedly to exit from the
menu.
DS1067-035A
WAIT PLEASE
64
UT01:MASTER
TEST
TEST
TEST INPUTS
TEST INPUTS
IN PROGRESS...
TEST INPUTS
TEST RESULT
UT01:MASTER
TEST
TEST
TEST OUTPUTS
TEST OUTPUTS
CONTROL PANEL
CONTROL PANEL
UC.U1:
U01
TEST OUTPUT
EXPANSIONS
LBT8633

Advertisement

Table of Contents
loading

This manual is also suitable for:

1067/042

Table of Contents