Return Call; Call Time Delay - urmet domus 1067/032 Programming Manual

Bus control panel 8/32 inputs
Table of Contents

Advertisement

4.14.20 Return call

If desired, the installer can enable the Return Call function for remote management operations. In this way it is possible
to perform a remote connection to 1067 system with a PC provided with FastPro 1067/001software, to call 1067 control
panel and to be immediately and automatically recalled by the control panel. In this way the telephone connection cost is
charged to the control panel user.
For Return Call it is possible to choose:
Disabled: the control panel, after receiving the call, continues with the connection procedure with FastPro 1067/001;
the telephone call cost is charged to the installer or to the remote management centre.
Type A: the control panel after answering the call, withdraws from the telephone line and then re-calls the first
Modem type number stored between those programmed.
Type B: the control panel after answering the call, withdraws from the telephone line and then re-calls the specific
phone number sent by FastPro 1067/001 during the previous connection; the cost of the telephone call is borne by
the owner of the control panel.
If configuration Type A is used, an additional security feature for the connection is implemented, because the link will be
possible only with a specific telephone number programmed during installation.
To set the Return Call follow the instructions below:
1. Enter on the keypad the Installer code (default 000000) and press OK key.
2. Press MENU key.
3. Press ▼ key until "TELEPHONE DIALER" appears on the display.
4. Press OK key to confirm.
5. Press ▼ key until "ADVANCED" appears on the display. Press OK key to confirm.
6. Press ▼ key until "RETURN CALL" appears on the display. Press OK key to confirm.
7. Select with ▼ and ▲ keys if the Return Call is disabled or enabled as type A or type B.
Press OK key to confirm.
8. Press ESC key repeatedly to exit from the menu.

4.14.21 Call time delay

In order to avoid false alarms, it is possible to delay the sending of vocal calls and SMS. In this case, the communicator,
after the event that generates burglar alarm has occurred, wait for 30 seconds before starting the vocal calls and SMS
cycle. If, within 30 seconds, the Master code or a User code is entered or a key is inserted provided that it is enabled to
operate on that zone from which the alarm started, vocal calls and SMS for burglar alarm are cancelled.
Warning: call time delay does not affect the sending of numerical or modem calls, that will be sent as soon as the
event occurs.
To set Call time delay follow the instructions below:
1. Enter on the keypad the Installer code (default 000000) and press OK key.
2. Press MENU key.
3. Press ▼ key until "TELEPHONE DIALER" appears on the display.
4. Press OK key to confirm.
5. Press ▼ key until "ADVANCED" appears. Press OK key to confirm.
6. Press ▼ key until "CALL TIME DELAY" appears. Press OK key to confirm.
7. Select with ▼ and ▲ keys if the call time delay is enabled or disabled and press OK key
to confirm.
8. Press ESC key repeatedly to exit from the menu.
DS1067-035A
52
UT00:INSTALLER
TELEPHONE DIALER
TELEPHONE DIALER
PHONE NUMBERS
TELEPHONE DIALER
ADVANCED
ADVANCED
RETURN CALL
RETURN CALL
RET.CALL DISABLE
UT00:INSTALLER
TELEPHONE DIALER
TELEPHONE DIALER
PHONE NUMBERS
TELEPHONE DIALER
ADVANCED
ADVANCED
CALL TIME DELAY
CALL TIME DELAY
ENABLE
LBT8633

Advertisement

Table of Contents
loading

This manual is also suitable for:

1067/042

Table of Contents