Periodic Communication Test; Remote Control Backup - urmet domus 1067/032 Programming Manual

Bus control panel 8/32 inputs
Table of Contents

Advertisement

4.14.16 Periodic communication test

1067/032 or 1067/042 control panel can automatically call, at fixed time intervals, remote management (modem) or alarm
reception centres (numerical) if they need a periodical confirmation for system correct operation.
The Periodic communication test can also be toward phone numbers into vocal mode.
It is possible to select the time interval between two calls among 1, 4, 8, 12, 24, 48 (=2 days), 72 (=3 days), 96 (=4 days),
120 (=5 days), 144 (=6 days) and 168 (=1 week) hours.
The time interval count will start at synchronization hour programmed by the menu.
To configure and activate the cyclic call follow the instructions below:
1. Enter on the keypad the Installer code (default 000000) and press OK key.
2. Press MENU key.
3. Press ▼ key until "TELEPHONE DIALER" appears on the display.
4. Press OK key to confirm.
5. Press ▼ key until "PERIOD COMM TEST" appears.
6. Press OK key to confirm. Select with ▲ and ▼ keys if it is disabled or enabled as 24H or
SYSTEM ON (depending on the total arm of the configured zones) and confirm the
selection with OK key.
7. If DISABLE has been selected, go to step 13; otherwise "24H" or "SISTEM ON"appears.
Press OK to confirm the selection.
8. Select with ▲ and ▼ keys the telephone number to which the periodic communication test
is sent and confirm the selection with OK key.
9. Press ▼ key until "SET HOUR" appears on the display. Press OK key to confirm.
10. Enter the time (hour and minutes) of the first call; the programmed time indicates the start
of the interval between a call and the next one. Confirm the entered time with OK key.
11. Press ▼ key until "INTERVAL" appears on the display.
12. Press OK key to confirm. Select with ▲ and ▼ keys the interval time, in hours, between
the periodic communication test and confirm the selection with OK key.
13. Press ESC key repeatedly to exit from the menu.

4.14.17 Remote control backup

This function manages the calls for any event sent to the telephone numbers programmed as Numerical and Modem. If
Backup function is enabled, if the first Numerical number and the first Modem number answers the call, no other calls will
be sent for that event to other numbers programmed in the same mode. If the first call is not successful, the control panel
sends the call to the next number and so on, up to correct sending/reception of the event to be signalled, or up to the end
of attempts. A call is defined as successful when it has received the acknowledgment (correct sending confirmation) by
the reception centre. By disabling the Backup function, the communicator performs anyway calls to all the numbers
programmed as numerical or modem
To enable Remote control backup function follow the instructions below:
1. Enter on the keypad the Installer code (default 000000) and press OK key.
2. Press MENU key.
3. Press ▼ key until "TELEPHONE DIALER" appears on the display.
4. Press OK key to confirm.
5. Press ▼ key until "REM CTRL BACKUP" appears.
6. Press OK key to confirm. Select with ▲ and ▼ keys if the call is disabled or enabled
7. Press ESC key repeatedly to exit from the menu.
DS1067-035A
50
UT00:INSTALLER
TELEPHONE DIALER
TELEPHONE DIALER
PHONE NUMBERS
TELEPHONE DIALER
PERIOD COMM TEST
PERIOD COMM TEST
DISABLE
24 H
ASSIGN TEL N.
ASSIGN TEL N.
T01:xxxxxxxx
24 H
SET HOUR
SET HOUR
HOUR
12:00
24 H
INTERVAL
INTERVAL
1h
UT00:INSTALLER
TELEPHONE DIALER
TELEPHONE DIALER
PHONE NUMBERS
TELEPHONE DIALER
REM CTRL BACKUP
REM CTRL BACKUP
ENABLE
LBT8633

Advertisement

Table of Contents
loading

This manual is also suitable for:

1067/042

Table of Contents