Tamper Alarm; Wrong Code Alarm - urmet domus 1067/032 Programming Manual

Bus control panel 8/32 inputs
Table of Contents

Advertisement

3.1.3

Tamper alarm

It is the alarm which is generated if somebody tries to tamper the system. It is always (24H) active and is temporarily
disabled by putting the system to maintenance status.
generated if...
The alarm is generated regardless of the zones status (24h).
activates...
Is stored...
Is displayed...
is held...
is stopped by...
3.1.4

Wrong code alarm

It is the alarm which is generated if somebody tries to identify a valid code to deactivate the system. It is always (24H)
active and is temporarily disabled by putting the system to maintenance status.
generated if...
The alarm is generated regardless of the zones status (24h).
activates...
is stored...
is displayed...
is held...
is stopped by...
DS1067-035A
a Tamper is opened (control panel, keypads, or radio devices like 1058/ 101; 201; 405; 035)
the SAB line of the control panel or expansions is opened or unbalanced
a double balancing input is unbalanced (short circuit or wires cut)
an input programmed as Tamper is opened
a device connected on the bus does not answer for many consecutive times
a radio device will not answer to the relevant radio expansion for a time higher than the pre-
selected configuration (Supervision)
a radio device extrinsic to the system is loading or jamming the radio band of the 1067/010
expansion (Jamming)
the outputs programmed as Tamper and Burglar/Tamper that have at least one shared zone
(for double balancing inputs). In the other cases it activates the Tamper outputs regardless of
the zones.
the communicator for voice, SMS, modem or numerical sending of the respective Tamper
alarm message (if programmed)
In the event log
in volatile tamper memory
on keypads
on readers
for Burglar/Tamper/Panic Alarm Time
entering of a valid code in the keypad
insertion of a valid key
a zones disarm command given by a key input
a DTMF disarm command entered with a phone call to the control panel
disarm command from remote control having at least one shared zone with the input which
has generated the event.
a wrong code is entered four consecutive times (the count is reset by entering a valid code)
the outputs programmed as Tamper and Burglar/Tamper that have at least one zone shared
with the keypad where the wrong code has been entered.
the communicator for modem or numerical sending of the respective and detailed wrong
code alarm description (if programmed)
in the event log
in tamper volatile memory
on the keypads which have at least one zone shared with the keypad where the wrong code
has been entered.
on the readers which have at least one zone shared with the keypad where the wrong code
has been entered.
for burglar/tamper/panic alarm time
entering of a valid code in the keypad
insertion of a valid key
a zones disarm command given by a key input
a DTMF disarm command entered with a phone call to the control panel
disarm command from remote control having at least one shared zone with the input which
has generated the event.
12
LBT8633