Input Exclusion Event; Acoustic Signallings; Entry/Exit Time Signalling; Arm Warning - urmet domus 1067/032 Programming Manual

Bus control panel 8/32 inputs
Table of Contents

Advertisement

3.1.22

Input exclusion event

generated if...
activates...
is signalled...
is stored...
at input reinsertion,
the control panel...
For more details, see § 5.8 Inputs exclusion and inclusion and § 4.5.1 Arming mode – Standard / Autoexclusion / Block
arming.
3.2

ACOUSTIC SIGNALLINGS

On the keypads buzzer can be activated the following signallings.
3.2.1

Entry/exit time signalling

generated if...
is held...
activated on...
3.2.2

Arm Warning

generated if...
is held...
activated on...
3.2.3

Gong

generated if...
activated on...
3.2.4

Output radio device status report (sirens)

Generated if...
Activated on...
Is displayed...
DS1067-035A
inputs are manually excluded
if the system autoexcludes inputs open at activation (if programmed)
if the system excludes inputs or owing to "alarms count" overflow (if programmed)
excluded input programmed outputs having at least one zone shared with excluded input
the communicator for numerical or modem sending of the respective Input excluded
message (if programmed)
by excluded inputs red LED on keypads having at least one zone shared with excluded input
into Event log
into excluded inputs list
activates the communicator for numerical or modem sending of the respective Input included
message (if programmed)
stores input reinsertion into Event log
deactivates excluded inputs programmed outputs associated to zones having no more
excluded inputs
puts off excluded inputs red LED on keypads associated to zones having no more excluded
inputs
arming takes place and the keypads have enabled the acoustic signal (buzzer) for the time
entry/exit time
for the delay time of inputs delayed
enabled keypads
buzzer programmed outputs having at least one zone shared with activation
is started the Warning time programmed for a zones arm command given by the timing
programmer
until the zones arm or insertion of a "time delayed"
enabled keypads and associated items
insertion Warning programmed outputs having at least one zone shared with activation
is opened an input, with Gong additional function enabled, and all the associated zones are
not active
enabled and associated keypads with 2 consecutive beeps
Gong programmed outputs having at least one shared zone - for 1 second
arming/disarming one or several zones or the whole system, if properly programmed.
system external sirens
on sirens with only acoustic or acoustic and optical warning:
1058/405 arming = 1 beep + 1 blinking; disarming = 2 beep + 1 blinking in sequence
18