Fire Reset Event; Technological Event; Door Opener Event; Courtesy Light Event - urmet domus 1067/032 Programming Manual

Bus control panel 8/32 inputs
Table of Contents

Advertisement

3.1.10

Fire reset event

generated if...
activates...
is stored...
besides...
Warning: in case of "fire alarm" signalling and subsequent alarm manual resetting, environmental conditions
have to be restored in premises where the alarm was generated and the detector has to be checked to have been
armed again in order to be able to detect a new alarm situation.
3.1.11

Technological event

System 1067 provides the capability to manage some domotics (heating activation, garden irrigation management, etc.)
functions through "technological events", "door opener event" and "courtesy light event".
"Technological events" and "courtesy light event" are always active (24H), while "door opener event" is only active when
zones are not active.
generated if...
activates...
is stored...
is held...
3.1.12

Door Opener Event

generated if...
activates...
is stored...
is held...
3.1.13

Courtesy Light Event

generated if...
activates...
is held...
3.1.14

Failure alarm from a Failure input

System 1067 can be paired to the control of devices provided with a "failure" output.
generated if...
The alarm is generated regardless of the zones status (24h).
activates...
is stored...
is displayed...
is stopped by...
after the solution of
• it activates the communicator for numerical sending of the respective message of failure
the problem the
control panel...
• turns off the failure LED on keypads and readers
• stores in the event log the failure end
• deactivates the outputs programmed as failure
DS1067-035A
a fire reset input is opened
for 1 second the outputs programmed as fire reset that have at least one zone shared with
the input that generated the event
in the event log
stops the respective fire alarm
resets the fire alarm volatile memory
turns off the LED on the keypads and readers that signalled the event
a technological input is opened
the outputs programmed as Technological that have at least one zone shared with the input
that generated the event
the communicator for voice, SMS modem or numerical sending of the respective
technological Service message (if programmed)
in the event log
until is open at least one of the inputs programmed as Technological with at least one zone
shared with the input
a Burglar input is opened belonging to one or more zones to which Door Opener additional
function was enabled. All zones associated to the input must be not active.
a key programmed as "access control" is inserted associated to one or more zones. All zones
associated to the key must be not active.
Door Opener programmed outputs associated to at least one input zone or key zone.
into Event Log in case of actuation caused by a key
about 2 seconds
a Burglar input is opened belonging to one or more zones to which Courtesy Light additional
function was enabled.
Courtesy Light programmed outputs associated to at least one input zone.
about 3 minutes
an input programmed as Failure is opened
the outputs programmed as Failure that have at least one zone shared with the input that
generated the event
the communicator for voice, modem or numerical sending of the respective Failure message
(if programmed)
in the event log
into failure and fault list
with the failure yellow LED on the keypads
with the yellow LED on the readers
when the input programmed as Failure is closed
alarm end (if programmed)