3.1.15

Telephone failure alarm

generated...
on PSTN line:
on GSM channel:
The alarm is generated regardless of the zones status (24h).
activates...
is stored...
is displayed...
is stopped by...
on PSTN line:
on GSM channel:
after the solution of
the problem the
control panel...
3.1.16

LAN failure alarm

generated...
The alarm is generated independently of zones status (24h)
activates...
is stored...
is displayed...
is stopped by...
after solving the
problem, control
panel...
3.1.17

System failure alarm

generated if...
The alarm is generated regardless of the zones status (24h).
activates...
is stored...
is displayed...
is stopped by...
after the solution of
the problem the
control panel...
DS1067-035A
after 3 automatic and consecutive failed PSTN tests
if, with tones control enabled, after an event to be sent, when the line is seized the dial tone
is not detected for 3 consecutive times.
in case of permanent absence of field
if the PIN code is wrong
without SIM or without credit used up
the outputs programmed as Telephone failure
the communicator for voice, modem or numerical sending of the respective Telephone failure
alarm message (if programmed)
in the event log
into failure and fault list
with the failure yellow LED on the keypads
with the yellow LED on the readers
when the telephone failure has been repaired, that is with a successful call on PSTN line, or
with a successful automatic PSTN test.
a successful phone call, carried out on GSM channel, or at the field strength return
activates the communicator for voice, modem or numerical sending of the respective
message of telephone failure alarm end (if programmed)
turns off the failure LED on keypads and readers
stores in the event log the telephone failure end
deactivates the outputs programmed as telephone failure
after 3 consecutive failed tries to send the event on LAN Ethernet channel
the communicator for voice, modem or numerical sending of relating LAN Failure Alarm (in
vocal mode, "system failure" message is sent).
into Event log
into failure and fault list
by failure yellow LED on keypads
by yellow LED on readers
LAN failure restore, that is with a successful communication on LAN Ethernet channel
activates communicator for numerical sending of relating end of LAN Failure Alarm message
(if programmed)
puts off failure LED on keypads and readers
stores end of LAN Failure into Event Log
a fault occurs on system supply voltages
a fault occurs on devices dialogue
a Data flash fault occurs
the outputs programmed as System failure
the communicator for voice, modem or numerical sending of the respective system failure
alarm message (if programmed)
in the event log
into failure and fault list
with the failure yellow LED on the keypads
with the yellow LED on the readers
the solution of the problem
activates
the communicator for voice, modem or numerical sending of the respective
message of failure alarm end (if programmed)
turns off the failure LED on keypads and readers
stores in the event log the failure end
deactivates the outputs programmed as System failure