11. Press ESC key to go to the upper level of the menu.
12. Press ▼ key; "COMMANDS TYPE" appears.
13. Press again OK key and select with ▼ and ▲ keys the day type (working, pre-holiday and
holiday ) to be configured.
14. Confirm the selection with OK key.
15. Press again OK key to select the command number, from 01 to 08.
16. Press OK key to confirm. Enter with keys the time for the planned programmer actions.
(midnight = 00:00) and confirm the entered time with OK.
17. Press ▼ key until "COMMAND TYPE" appears and confirm the selection with OK key.
18. Select among "NO ACTION", "ARM" (ENABLE) and "DISARM" (DISABLE), and confirm
the selection with OK key. With "ARM" (ENABLE) and "DISARM" (DISABLE) it is also
necessary to select among "ZONES", "OUTPUTS USERS", "KEYS", by using ▼ and ▲
keys and confirm with OK key.
19. According to the selection can appear:
USERS: Select with ▼ and ▲ keys the user to be enabled/disabled and confirm the selection
with OK key.
KEYS: Select with ▼ and ▲ keys the key to be enabled/disabled and confirm the selection
with OK key.
ZONES: Select the zones to be enabled/disabled with ◄ and
selection with OK key. Valid zones are indicated by squares.
OUTPUTS: Confirm the selection with OK key (on the commandable output only).
20. Now it is possible to add other actions to the selected day type (follow the same
procedure from step 13 and select a new action) or program another day type (follow
the same procedure from step 8).
21. After programming the commands for the different day types, press ESC key repeatedly,
back to "COMMANDS TYPE".
22. Press ▼ key; "WARNING TIME" appears
23. Press OK key. Select the warning time with ▼ and ▲ keys and confirm the selection with
OK key. Available values are No warning, 5, 10, 15 and 20 minutes. The warning time is
applied to all the commands of all the days of the week.
24. Press ESC repeatedly to exit from the menu.
4.18.3

Command deleting

To delete a command follow the procedure for programming; in operation selection choose "NO ACTION". To stop all the
programming procedures it is not necessary to delete them, but it is sufficient to disable them (see paragraph 5.7.3
Timing programmer disabling).)

4.19 PROGRAMMING BY COMPUTER

All the configurations made by 1067/021 keypad can carried out, in an easier and friendly way, also with a PC and Urmet
FastPro 1067/001 software (release 2.10 or higher). All instructions for its use are described in the software manual. It is
necessary to enable the access by PC as follows: Master menu – Enable – Advanced – Enable remote access.
The control panel can be programmed by PC in the following ways:
Local, by connecting the PC to the control panel via an USB port.
Remote, by connecting the PC to the control panel via a modem and the telephone line; this connection allows also
system remote maintenance and management.
Deferred, by storing the programming planned in laboratory on an USB key and then transfer it in the control panel.
DS1067-035A
► keys and confirm the
62
P.O.
COMMANDS TYPE
COMMANDS TYPE
WORKING DAY
WORKING DAY
COMMAND N:01
COMMAND N:01
COMMAND HOUR
COMMAND N:01
COMMANDS TYPE
COMMANDS TYPE
NO ACTION
USERS
Us02:...
KEYS
KE01:...
ZN01:...
□□□...
TIME PROGRAMMER
COMMANDS TYPE
TIME PROGRAMMER
WARNING TIME
WARNING TIME
NO WARNING
LBT8633