28. Press OK key to confirm.
Give the input a descriptive name, by using the keypad (for further information see §
4.2). Name maximum length is 10 digits.
29. Press OK key to confirm. "NAME" appears.
30. Program the other 1067/010 expansion inputs by following the same procedure from
step 6.
31. At the end press ESC repeatedly to exit from the menu.
4.10.8

Radio output programming (SIRENS)

The 1067 system controls max. 15 general purpose outputs; a single radio expansion (1067/010) can contextually
control just two outputs (sirens).
4.10.9

Radio output coding

Every input has two codes: a physical one and a logical one. The two addresses are displayed according to the following
diagram:
more in detail
dove:
dd is the radio device type associated to an 1067/010
XX is the progressive numbering of radio devices acquired as inputs
Y is the input numbering in radio XX device (physical address)
ZZ is the input logical address, composed by two digits, that the control panel assigns with a system progressive
numbering when radio devices are acquired.
The physical address is useful for the installer during system installation and maintenance phase. On display may appear
with another notation (EW= radio expansion, HP= external sirena).
The output customizations define the sirens programming, in order to be activate for a specific events.
System 1067 identifies the inputs on display with physical address, logical address and name, while vocal or numerical
alarms are identified only with logical address and customized message, if present.
During acquisition phase of 1067/010, expansions, the control panel assigns automatically a progressive logical
address in sequence, to the control panel outputs and eventual other 1067/008 expansion outputs.

4.10.10 Radio output customizations

The output customizations define the sirens programming, in order to be activate for a specific events.
For more details on single functions, see Chapter 3 Alarms, Events and Signalling.
The table below lists the customizations available for the sirens:
For complete description relevant to the only customizations applicable to radio outputs, refer to the description
provided at the paragraph dealing with wired devices since it is the same one: § 4.7.3 – Output customizations.

4.10.11 Status report

The table below lists the available applicable functions:
For further details concerning the "Status report" function please refer to § 3.2 Acoustic Signalling.
DS1067-035A
logical address: physical address
ddXX UY:
Device
Radio siren
Burglar (default)
Pre-alarm
Tamper
Customizations
Audible panic
Fire alarm
Device
Radio siren
Disabled (default)
Blinking only
Status report
Siren + blinking
36
UZZ
NAME
In01:...
RADIO DEVICES
EW01:EW01
LBT8633