Timing Programmer Enabling; Timing Programmer Disabling; Inputs Exclusion And Inclusion; Input Exclusion - urmet domus 1067/032 Programming Manual

Bus control panel 8/32 inputs
Table of Contents

Advertisement

5.7.2

Timing programmer enabling

To activate the timing programmer it is necessary to enable it.
Enabling is possible only if there are programmed timed commands.
To enable the timing programmer follow the instructions below:
1. Enter on the keypad the Master code (default 111111) and press OK key.
2. Press MENU key.
3. Press ▼ key until "ENABLE" appears on the display.
4. Press OK key to confirm.
5. Press ▼ key until "TIMED COMMANDS" appears and confirm with OK key.
6. Press ▼ key to select ENABLE and confirm with OK key.
7. Press ESC key repeatedly to exit from the menu.
If enabling is accepted, the green LED "clock" on the keypads will turn on.
5.7.3

Timing programmer disabling

The procedure to disable the timing programmer is similar to the enabling procedure, described in paragraph 5.7.2.
The only difference consists in selecting "DISABLE" at step 6.
By disabling the timing programmer any timed commands will be carried out. However timed commands are kept in
memory and will be active after the next Timing Programmer enabling.
5.8

INPUTS EXCLUSION AND INCLUSION

In particular circumstances it may be necessary to temporarily exclude an input from the system, for example to carry out
a test or because the connected detector is damaged and signals a false alarm, preventing the system arm. The
exclusion of an input can reduce the safety provided by the system.
If the input is double balancing type, its exclusion prevents both alarm and tamper. However, its opening is signalled by
the lighting of the open inputs LED of associated keypads.
Warning: can be excluded only inputs with EXCLUDABLE parameter, enabled with the programming procedure.
5.8.1

Input exclusion

To exclude an input follow the instructions below:
1. Enter on the keypad a user code or the Master code and press OK key.
2. Press MENU key.
3. Press ▼ key until "SETTINGS" appears on the display.
4. Press OK key to confirm. "INCLUDE/EXCLUDE" appears.
5. Press OK key. Appears the list of inputs that can be excluded.
6. Select with ▲ and ▼ keys the input to be excluded and confirm the selection with OK key.
7. Confirm with OK key.
Exclusion message will appear and also "excluded inputs" LEDs on the keypads will turn on.
8. Press ESC key repeatedly to exit from the menu.
DS1067-035A
77
UT01:MASTER
ENABLE
ENABLE
TIMED COMMANDS
TIMED COMMANDS
ENABLE
UT01:MASTER
SETTINGS
SETTINGS
INCLUDE/EXCLUDE
INCLUDE/EXCLUDE
IN01:...
IN01:...
EXCLUDE
OK?
EXCLUDE
IN01:...
LBT8633

Advertisement

Table of Contents
loading

This manual is also suitable for:

1067/042

Table of Contents