4.7.4

Output programming

To program an output follow the instructions below:
1. Enter on keypad the Installer code (default 000000) and press OK key.
2. Press MENU key.
3. Press ▼ key until "PROGRAMMING" appears on the display.
4. Press OK key to confirm.
5. Press ▼ key until "OUTPUTS" appears.
6. Press OK key to confirm. Select with the ▼ key if programming the control panel outputs
or those of any expansion configured.
7. Press OK key to confirm.
Select with ▼ key the desired output.
8. Press OK key to confirm.
9. Press OK key and after ▼ key until "OUTPUT TYPE" appears.
10. Press OK key to display the types of available outputs (N.L. – N.H. – Not used). Select
desired type with▼ and ▲ keys and confirm it with OK key.
11. Press ▼ key until "ASSIGN" appears.
12. Press OK key to confirm.
13. Press OK key to select SYSTEM and with ▼ and ▲ keys select "DO NOT ASSIGN", in
order not to associate the output to any zone, or "ASSIGN" to associate it to all the zones,
by confirming selection with OK key.
14. Otherwise it is possible to associate to the output the single zones by pressing ▼ key until
"ZONES" appears.
15. Press OK key to confirm.
Select desired zones and press OK key to confirm
16. Press repeatedly ESC key until "ASSIGN" - "ZONES" appears again.
17. Press ▼ key until "CUSTOMIZE" appears.
18. Press OK key to display the configuration of available outputs. Select desired configuration
with▼ and ▲ keys and confirm it with OK key.
19. Press▼ key until "NAME" appears on the display.
20. Press OK key to confirm.
Give the output a descriptive name, by using the keypad (for further information see
paragraph 4.2 Alphanumeric characters input).
21. Press OK key to confirm. "NAME" appears again.
22. Program the other control panel outputs by following the same procedure from point 7.
23. If the system has expansions, press ESC key until "CONTROL PANEL" appears again on
the display.
24. Press ▼ key to display "EXPANSIONS".
Confirm by pressing OK key, select the desired expansion with ▼ and ▲ keys, confirm
selection by pressing OK key, then program all its outputs with the same procedure used
for control panel outputs programming.
25. Program all the expansions and at the end press ESC repeatedly to exit from the menu
NOTE: commandable outputs maximum number is 10. The logical address of these outputs must be from 01 to 10.
DS1067-035A
30
UT00:INSTALLER
PROGRAMMING
PROGRAMMING
ZONES
PROGRAMMING
OUTPUTS
OUTPUTS
CONTROL PANEL
CONTROL PANEL
UC.U1:
U01
UC.U1:
U01
OUTPUT TYPE
UC.U1:
U01
ASSIGN
ASSIGN
SYSTEM
ASSIGN
ZONES
ZN01:...
□□□□□□
UC.U1:
U01
CUSTOMIZE
UC.U1:
U01
NAME
NAME
U01:...
UC.U1:
U01
NAME
OUTPUTS
CONTROL PANEL
OUTPUTS
EXPANSIONS
LBT8633

Advertisement

Table of Contents
loading

This manual is also suitable for:

1067/042

Table of Contents