Available commands for the timing programmer are the following:
Command
Zones arm
Zones disarm
Commandable output activation
Commandable output
deactivation
Key or user code enabling
Key or user code disabling
Warning: the timing programmer does not manage midweek holidays (Christmas, St. Stephen's day, New Year's
Day, Epiphany, Easter Monday, August holiday, etc.), that will be considered as the day of the week in which they
occur.
The time programming is always stored in the control panel and it is possible to enable or disable it, without deleting the
stored configurations, by following the procedures described in paragraphs 5.7.2 Timing programmer enabling and 5.7.3
Timing programmer disabling.
The time programming status (enabled or disabled) is displayed in the keypad by the timing programmer LED [7].
Commands performed by the timing programmer are active until the opposite command is given (by the programmer or
by a user with keypad or reader): in fact the programmer sends commands, but it does not check system or outputs
state.
Example of operation
An office is open from Monday to Friday, from 9 a.m. to 6 p.m. Days from Monday to Friday have been programmed as
working days, Saturday and Sunday as holidays. The first command set in the working day, at 8:55, is the burglar system
disarming and the last, at 18:05, the burglar system arming; during holidays there are no commands.
In practice, with enabled timing programmer, the system is automatically armed at the end of every working day and it is
disarmed in the morning of the following day. After arm on Saturday evening, it is not deactivated until Monday morning,
because on Saturday and Sunday there are no disarm commands.
If it is necessary to enter in protected premises, a user can manually disarm the system with the keypad or the reader
also on Saturday and Sunday. He must remember to arm again the system when he leaves the office, otherwise
premises will be without any protection.
4.18.2

Programming procedure

Suggestion: before starting programming procedure, fill in the specific tables (see paragraph 7.18 Timing
programmer): your work will become easier.
Warning: for timing programmer correct operation, control panel date and time must be correct (to change time
and date see paragraph 4.4 Time/date setting).
To program the timing programmer follow the instructions below:
1. Enter on the keypad the Installer code (default 000000) and press OK key.
2. Press MENU key.
3. Press ▼ key until "SETTINGS" appears on the display.
4. Press OK key to confirm.
5. Press ▼ key until "TIME PROGRAMMER" appears and confirm with OK key.
6. "DAY TYPE" appears; Press OK key to confirm.
7. "MONDAY" appears; Press again OK key.
8. Select with ▼ and ▲ keys the day type (working, pre-holiday and holiday ) to be assigned
to the displayed day of the week. Confirm the selection with OK key.
9. Go to the next day with▼ key.
10. Follow the same procedure from step 8. When every day of the week has the type
indication, go to step.
DS1067-035A
Description
It activates the zone/zones
It deactivates the zone/zones
It activates the commandable
output
It deactivates the
commandable output
It enables a key or a code
It disables a key or a code
61
Notes and examples
It is the remote-controlled output.
Domestic help or office cleaners: by combining the
two commands it is possible to allow the domestic
help to stay at home or cleaners in office, only in
given days and time.
UT00:INSTALLER
SETTINGS
SETTINGS
INCLUDE/EXCLUDE
SETTINGS
TIME PROGRAMMER
DAY TYPE
MONDAY
MONDAY
WORKING DAY