4.3.1 AUXILIARY INPUT.
The auxiliary input is unbalanced (terminal pins In and –RV). The input is configured by default as "contact", for example for a magnetic contact
on a door, but it can also be configured to connect a rolling shutter detector.
.
WARNING:.
Auxiliary inputs are always associated to the partition A.
The auxiliary input generates only a generic intrusion alarm, that can not be punctually located with dedicated led.
4.3.2 TAMPER INPUT
The keypad tamper input (terminal pins Sab and –Rv) is designed for connection of the front tamper installed on the support (for details, see
paragraph.3.3 Management keypad). The figure 26 shows the connection diagram.
§
If the input IN is unused, it must be connected to ground (-RV).
4.4 MAINS AND BATTERY CONNECTIONS
1061 CONTROL PANEL
POWER
The.control.panel.power.supply.must.be.connected.to.0÷40V~.mains.with.a.-core.mains.cable.with.double.insulation.and.a.magnetothermic.
switch..It.is.suggested.to.connect.the.control.panel.power.supply.before.the.residual.current.circuit.breaker,.in.order.to.be.able.to.disconnect.
mains.and.at.the.same.time.keep.active.the.alarm.system.power.supply..
On.the.power.supply.unit,.the.screw.terminal.pins.for.0÷40V~ cable are labelled as PH (phase) and N (neutral); in the near fin used for power
supply fixing there is a slot for the cable tie passing, in order to block cables.
The power supply output (OUTPUT) is connected by default to the terminal pins POWER of the motherboard. The backup battery must be
connected.to.cables.with.faston.connectors.already.installed.in.factory:.the.red.cable.must.be.connected.to.the.battery.positive.pole,.the.black.
cable.to.the.negative.pole.
DS1061-015B
CONTROL PANEL
+
LA
LB
-
MAGNETIC
CONTACT
Figure 26 – Connection diagram for keypad auxiliary and tamper inputs
Figure 27 – Connection to mains
Figure 28 – Fixing of 220÷240V~ mains cable
KEYPAD
+
LA
LB
-
IN
SAB
TAMPER
-RV
1069/416
MAGNETOTHERMIC
SWITCH
220÷240V~
MAINS
MAINS
50/60Hz
RESIDUAL CURRENT
CIRCUIT BREAKER
USERS
19