Removing The Guide Shoes Of The Developer And Fixer Racks - Kodak X-Omat M43 PROCESSOR Service Manual

Hide thumbs Also See for X-Omat M43 PROCESSOR:
Table of Contents

Advertisement

SERVICE MANUAL

Removing the GUIDE SHOES of the DEVELOPER and FIXER RACKS

[1] Check that:
• PROCESSOR is de-energized
• TOP COVER is removed
[2] Remove the RACK from the PROCESSOR. To prevent contamination of the processing solutions, use the
DRIP TRAY and the SPLASH GUARD (FIXER RACK only).
[3] Rinse the RACK with warm water. Using a clean, damp, lint-free cloth, wipe the ROLLERS to remove any
chemical residue.
[4] Remove the 2 SCREWS securing the GUIDE SHOES to the GUIDE SHOE BRACKET.
(a) Note the orientation of the long edge of the GUIDE SHOES.
(b) If you need to remove the GUIDE SHOE BRACKET, note its correct orientation for later installation.
[5] To install the new GUIDE SHOES, reverse the steps above.
Removing the GUIDE SHOES of the DEVELOPER and FIXER RACKS
Figure 9
SCREWS
LONG
EDGE
16
SCREWS GUIDE
SHOE
BRACKET
LONG
EDGE
GUIDE
SHOE
H130_0200HCA
H130_0200HA
September 1995 – 981090