Installing the Developer Filter
[1]
Remove the FILTER CAP and install the new

DEVELOPER FILTER.

[2]
Install the FILTER CAP.
Connecting the Drains
The processor is equipped to accommodate the separation of DEVELOPER, FIXER, and WATER effluent liquid.
The processor is shipped from the factory with a separate FIXER OVERFLOW/TANK DRAIN, AUXILIARY
FIXER TANK DRAIN, DEVELOPER OVERFLOW/TANK DRAIN, and AUXILIARY DEVELOPER TANK DRAIN.
See Figure ??.
To prevent severe corrosion, do not use brass or copper piping. To prevent contamination from
plumbing blockage, and to improve drainage, do not make solid drain connections to the
DEVELOPER, FIXER, or WASH WATER drains.
[1]
Connect the three 1.9 cm ( ⁄
DEVELOPER, FIXER, and WASH WATER DRAINS on the FEED END of the processor.
[2]
Route the tubing as required. Wash water waste can be routed directly to the BUILDING DRAIN. Do
not make a solid connection between the WASH WATER DRAIN and the FLOOR DRAIN.
32
3
in.) tubes, that you unpacked from the RECEIVING BIN, to the
4
DEVELOPER
FILTER
Figure 37 Installing a New
FILTER
CAP
H108_0068ACA
H108_0068AA
Developer Filter