Cleaning The Wash Inlet Bar - Kodak X-Omat M43 PROCESSOR Service Manual

Hide thumbs Also See for X-Omat M43 PROCESSOR:
Table of Contents

Advertisement

Cleaning the WASH INLET BAR

Important
This procedure applies to the United Kingdom only.
[1] Remove:
• TOP COVER
• BACK ACCESS PANEL
• DRYER RACK
• WASH RACK
[2] Drain the WASH TANK.
[3] Place a MIRROR under the WASH INLET BAR to check for obstructions in the holes in the INLET BAR.
[4] If the holes are obstructed, continue with the procedure.
Removing the WASH INLET BAR
Figure 65
Important
Some solution may leak. Be ready to wipe up any spilled solution.
[5] Remove the WASH INLET BAR.
[6] Clean the holes in the WASH INLET BAR.
(a) Use a solution of 50% vinegar and 50% water and a BOTTLE BRUSH TL-4833 or a TOOTHBRUSH to
clean the outside of the WASH INLET BAR.
(b) Wipe the WASH INLET BAR with a clean, damp, lint-free cloth to remove the vinegar and water
solution.
[7] Energize the PROCESSOR.
[8] Use the Service Routine to operate of the WATER INPUT SOLENOID. Operate the SOLENOID for at least
1 minute to rinse the WASH INLET BAR and the WASH TANK.
[9] Install:
• RACKS
• BACK ACCESS PANEL
• TOP COVER
981090 – September 1995
WASH INLET
MIRROR
BAR
Plumbing
H130_0193BCA
H130_0193BA
77