Removing the WASH RECIRCULATION PUMP (B2)
Removing the WASH
Figure 47
RECIRCULATION PUMP
output HOSE
SCREW
CLAMP (2)
input
HOSE
LOCK
WASHER
SCREW
WASHER
981090 – September 1995
TL-4571
WASH RE-
CIRCULATION
PUMP
P/J6
H130_0090CCA
H130_0090CA
[1] Check that you have completed all the steps on
Page 55 before you begin this procedure.
[2] Check that the WASH TANK is drained.
[3] To gain access to the WASH RECIRCULATION
PUMP, slide out the ELECTRICAL BOX from
the Drive side of the PROCESSOR.
[4] Disconnect CONNECTOR P/J6.
Important
Some solution may leak. Be ready to wipe up any
spilled solution.
[5] Use EXTENSION TOOL TL-4571 to loosen the
2 SCREW CLAMPS and disconnect the HOSES
from the WASH RECIRCULATION PUMP.
[6] Loosen the SCREW, LOCK WASHER, and
WASHER securing the WASH
RECIRCULATION PUMP to the frame of the
PROCESSOR.
[7] Install the WASH RECIRCULATION PUMP by
reversing the steps above.
[8] Check that you route the HOSE connected to the
WASH RACK so that it does not interfere with
accessing the ELECTRICAL BOX.
[9] Check that the water supply is turned on.
[10] Connect the main power and energize the
PROCESSOR.
[11] See the Diagnostics Manual, Publication Number
981093, and do the Service Routines below:
• WATER INPUT SOLENOID - operate the
SOLENOID to fill the WASH TANK
• WASH PUMP - operate the WASH PUMP
and check that water is pumped through the
WASH TUBES in the WASH RACK
Plumbing
57