Making the Plumbing Connections

Installing the DEVELOPER FILTER

DEVELOPER
FILTER
FILTER
CANISTER
H148_0021ACA
H148_0021AA

Connecting the Drains

The PROCESSOR can drain developer, fixer, and water separately. The PROCESSOR is shipped with a separate
FIXER OVERFLOW/TANK DRAIN, AUXILIARY FIXER TANK DRAIN, DEVELOPER OVERFLOW/TANK DRAIN,
and AUXILIARY DEVELOPER TANK DRAIN.
Warning
• DRAINS must be made of chemically resistant, non-corrosive material. Use PVC or equivalent.
• The DRAIN must have a minimum diameter of 7.6 cm (3 in.) and be free of obstruction.
• Drain service must comply with all local codes.
• The HOSES must slope gradually down to the DRAIN.
• To prevent possible biological growth, do not allow the drain TUBES to touch the FLOOR DRAIN.
[1] Remove the three 1.9 cm (3/4 in.) HOSES from the PREPACK CARTON. Connect the 3 HOSES to the
DEVELOPER, FIXER, and WASH WATER DRAINS on the feed end of the PROCESSOR.
[2] Route the tubing as required to comply with local codes for disposing of wash water that contains photographic
chemicals. Do not make a solid connection between the WASH WATER DRAIN and the FLOOR DRAIN.
5B6339 – January 1996
FILTER
CAP
[1] Remove the FILTER CAP.
[2] Carefully place a new DEVELOPER FILTER into
the FILTER CANISTER.
[3] Install the FILTER CAP.
Connecting the PROCESSOR