Draining the PROCESSOR TANKS

Caution
If using a Silver Recovery Unit, disconnect the Drain Tube from the input side of the Silver Recovery Unit before
you open the Drain Valve. This will avoid flooding. Drain the fixer solution into a container or directly into the floor
drain. Check the local codes before draining solutions into a floor drain.
[1] Drain the TANK by rotating the DRAIN VALVE KNOB in either direction
lock into place. When the TANK, is drained, close the DRAIN VALVE by rotating the DRAIN VALVE KNOB
1
turn in either direction.
4
Draining the TANKS
Figure 3
981090 – September 1995
Introduction
1
turn.You will feel the STEM
4
DRIVE VALVE KNOBS
H130_0019BCG
H130_0019BA