DEPENDING THE FAILURE TYPE THE FULL CONTROL COMPUTER WILL START A SPECIFIC
PROCEDURE :
WHEN SAFETY IS INVOLVED
Full stop + tumble
Full stop + safety time
Don't start
WHEN SAFETY IS NOT INVOLVED
Full stop + request for continue
Skip + continue
Continue
SPECIAL CASES :
For E11:Fill Time failure and E14:Heating time failure after overruling and erasing the
failure message, you can restart or stop the sequence, as Continue ? will be displayed.
Possible cause :
For E24:Defective Level sensor, E25:Defective Temperature sensor and E35:Wrong software
version the Failure message can only be erased by switching the power off and back on.
Fault 31:Initialisation fault inverter and 32:Verification fault inverter can be erased by switching
off the power. But as Fault 31 and 32 indicates that the frequency inverter is not loaded with the
correct parameter settings, the washing machine can be damaged when the inverter is functioning
with the wrong settings.
Do not use the washing machine before a technician has inspected the problem.
Fault 41:Service Due will occur over and over again until you have reset the cycle counter.
See Paragraph 8.5 how to reset the cycle counter.
Fault 57:Door Locked Continue >> START will occur when the "Door Lock Switch" stays locked
when opening the outer door on a MB90-140-180.
You can still unload the linen at the other compartments by overruling the error message by Pressing
the START button.
RESET KEY :
When you have overruled an error message and opened the door, Reset Key will be displayed.
This message warns the operator that the Key Switch is still in Program mode.
Before you can start a new program you have to turn the key switch back to Run mode.
! ! Reset Key ! !
Turn the key switch to Run mode.
100962 G
PUBLICATION DATE 24 JUN 2008.DOC
: the program is stopped but will run the tumble sequence
: the program is stopped and a safety time is started
: the program will not be started as long as the safety
conditions are not fulfilled
: a request to Continue ? the program is displayed
: the actual cycle step is skipped and the program continues
with the next step
: the program continues
- water supply inlets closed
- decreasing capacity of the heating elements