Primus RF6 Programming Manual page 62

Industrial washer extractors
Table of Contents

Advertisement

P:Pr XX Step XX
RPM : _ _
P:Pr XX Step XX
Supply ?
P:Pr XX Step XX
Supply A : 0 Sec
P:Soap Supply
Menu
Exit
P:Pr XX Step XX
On Time: _ _ Sec
60
• The suggested drum speed value depends on the machine
type.
• Check the corresponding table paragraph 3.4.
• The drum speed value can only be programmed within
certain limits.
• Insert the desired speed value. Press the ENTER button for
confirmation.
• If you don't want to get into the supply sub-menu, press the
ARROW DOWN button.
• Press the ENTER button to get into the supply sub-menu.
• Default: all the supplies are switched off. (time = 0)
• Liquid soap supplies can only be programmed if the selection
in the configuration menu is enabled.
• The supplies can be programmed for an interval time
between 0 and 99 seconds.
• The supply will not be activated if 0 Seconds is programmed.
• Up to 4 supplies can function at the same time at the same
Sequence.
If you have programmed more then 4 supplies an error
message will be generated. Put the time of the supplies back
to zero until not more than 4 non-zero time values are
remaining.
• The overview display shows the Supply Name and the
corresponding programmed time.
• Insert the desired supply time. Press the ENTER button for
confirmation.
• At the end of the Menu, when EXIT is displayed, you have to
press the ENTER button to leave the supply Menu.
Attention !
!
For Front Soap Hopper washing machines, the soap is
added by programming the supplies A to E. (X22/5 A to D)
External liquid soap pumps correspond with the supplies
F to K.
For Top Soap Hopper washing machines, the External liquid
Soap pumps correspond with the supplies D to N.
The number of external supplies that is available depends
on the machine type.
• The wash motor ON time can be programmed between 0 and
99 seconds.
• The wash motor OFF time can be programmed between 1
and 99 minutes.
• The suggested default values can be adapted in the
Initialisation menu.
PROGRAMMING MANUAL
100962 G
PUBLICATION DATE 24 JUN 2008.DOC