Programming the Wash Speed
Standard reversing wash speed is between ≅ 40 and 50 RPM. (≅ Verify exact value at table 3.4.B.)
For some special applications the drum should only turn very slowly.
- Speed Limits
The minimum programmable wash speed is 10 RPM.
The maximum programmable wash speed is 50 RPM.
Programming Extraction speed
R – RF machines :
F & X machines :
FF & XF & MB machines : Extraction ≅ [300 - 350] – [450 – (850) 1000] RPM
The speed value is only programmable for machines with inverter controlled motor.
An Intermediate spin between two sequences should be about ½ of the max spin.
Between 350 and 450 RPM (≅ Verify exact value at table 3.4.B.) it's not allowed to program a steady
speed, as the machine could VIBRATE TOO MUCH.
- Speed Limits
Check table 3.4.B with the minimum and maximum speed limits. The limits differ depending on the
maximum allowed g-force at high spin for each washing machine type.
Programming Supplies
Up to 4 Supplies can be programmed at the same time in a sequence.
For Front Soap Hopper washing machines, supplies have to be programmed to add the soap from the
hoppers.
If Liquid soap pumps have been installed on your washing machine, then these pumps will be
activated by programming a time value for the corresponding supply signal.
If a second drain valve has been installed, then there is 1 Liquid pump less that can be
programmed.
- Time Limits
The maximum programmable time is 99 Seconds
If the time is 0 Seconds then the supply will NOT be activated at the wash process.
ATTENTION !!!
!
IF FOR SOME SPECIAL APPLICATION MORE THAN 4 SUPPLIES MUST BE PROGRAMMED IN THE
SAME SEQUENCE, THIS CAN BE SOLVED BY PROGRAMMINGTHE SAME SEQUENCE TWICE; ONE
AFTER THE OTHER. SPLIT THE WATER LEVEL ( SO IT WILL TAKE WATER FOR THE SECOND FILL,
say 60%, 100%), STEP TIME, AND THE NUMBER OF SUPPLIES, OVER THE TWO SUBSEQUENT
SEQUENCES. PROGRAM A "NO DRAIN" BETWEEN THE TWO SEQUENCES TO AVOID DRAINING
THE WATER. SET TEMPERATURE THE SAME FOR BOTH PARTS.
20
Extraction ≅ 450 RPM (MFR)
Low Extraction ≅ 500 RPM (MFS PND)
High Extraction ≅ 850 - 1000 RPM (MFX PND - MFS PND)