FAILURE 300-353: MITSUBISHI INVERTER ALARM MESSAGE
If a Mitsubishi Inverter Alarm occurs, check the trouble shooting in the Mitsubishi inverter manual.
300 Err OC1 308 Err FAN 316 Err RET 324 Err OP2 332 Err MB5 340 Err E.3
301 Err OC2 309 Err OLT
302 Err OC3 310 Err BE
303 Err OV1 311 Err GF
304 Err OV2 312 Err OHT 320 Err IPF
305 Err OV3 313 Err OPT 321 Err UVT 329 Err MB2 337 Err ECT 345 Err IOH
306 Err THT
314 Err PE
307 Err THM 315 Err PUE 323 Err OP1 331 Err MB4 339 Err E.2
DIAGNOSE FOR FAILURE 300-301-302: OC-ERRORS
1. Check if there is no short circuit on the
output of the inverter. (loose wire of motor
cable,...)
2. Check if there is no short circuit in the
Terminal Box of the motor. (loose wire of
the motor cable, screws or other metal
pieces who can move inside the terminal
box.)
DIAGNOSE FOR FAILURE 303-304-305 : OV-ERRORS
If there is too much regenerative energy coming from the motor (working as a generator) to the inverter, the
voltage on the capacitors will become too high and the inverter goes into OV-alarm state.
1. Check if the correct machine type is
selected in the S-submenu
2. Check if there was a high unbalance during
extraction, which can be caused by putting
only half loads in the machine.
3. Check if the fault is persistent
DIAGNOSE FOR FAILURE 306: THT-ERROR
If the output current of the inverter is abnormal high for some time, the inverter will go into THT-alarm
state.
1. Check if the power supply is sufficient high
and stable during extraction with load.
2. Check if the drum rotates normally by hand.
(no abnormal high friction)
3. Check if the correct machine type is selected in
the S-Menu.
4. Check if the correct parameters have been
loaded in the inverter.
DIAGNOSE FOR FAILURE 307: THM-ERROR
If the motor current is higher than allowed for a longer time, the inverter will active the electronic
overcurrent protection to prevent the motor from overheating and the inverter will go into THM-alarm state.
1. Check if the drum rotates normally by hand.
(no abnormal high friction)
124
317 Err CPU 325 Err OP3 333 Err MB6 341 Err ILF
318 Err E.6
326 Err CTE 334 Err MB7 342 Err PTC 350 OD
319 Err E.7
327 Err P24
328 Err MB1 336 Err OSD 344 Err CDO 352 E.11
322 Err LF
330 Err MB3 338 Err E.1
Repair the short circuit.
If the wrong machine type is selected, enter the right
machine type
Put always a full load in the machine drum.
Do not put other material than textile linen (fabrics) in
the machine.
If the fault is persistent, contact the manufacturer
Repair the power supply.
Repair / clean what is necessary.
If the wrong machine type is selected, enter the right
machine type.
If the correct parameters are not loaded in the inverter,
load the correct parameters.
Repair / clean what is necessary.
PROGRAMMING MANUAL
335 Err FIN
343 Err PE2
346 Err SER
347 Err AIE
Repair the short circuit.
Make sure the screws are sufficiently tightened.
100962 G
348 USB
349 OS
351 EP
353 E.13
PUBLICATION DATE 24 JUN 2008.DOC