Primus RF6 Programming Manual page 32

Industrial washer extractors
Table of Contents

Advertisement

ATTENTION !!!
!
BE SURE THAT YOU HAVE SELECTED THE CORRECT MACHINE TYPE, OTHERWISE THE MACHINE
WILL NOT FUNCTION PROPERLY.
ATTENTION !!!
!
BY CHANGING THE MACHINE TYPE THE WASH PROGRAM'S KEPT IN THE EEPROM MEMORY
ARE NOT CHANGED.
AFTER CHANGING THE WASH MACHINE TYPE IT'S RECOMMENDED TO ERASE THE PROGRAM
MEMORY AND LOAD THE STANDARD WASH PROGRAM'S AGAIN.
THE WASH PROGRAM SETTINGS DIFFER FOR EACH MACHINE TYPE.
ATTENTION !!!
!
SELECTING RESET FACTORY IS RECOMMENCED IF A NEW MACHINE TYPE HAS BEEN
SELECTED. THIS WILL ENSURE THAT ALL THE DEFAULT SETTINGS OF THE NEW MACHINE TYPE
ARE LOADED.
C:Reset Factory
Settings?
C:Brightness
Display : 9
C:Frequency
Control:
Yes
C:Supply Voltage:
3 x 380 – 415 V + N
30
• All the Initialisation and Configuration Menu settings will be
cleared and the default Factory settings will be re-installed.
• This function should only be used at the initialisation of a new
Full Control Wash Computer.
• Select Yes or No and confirm by pressing the ENTER button.
• By selecting YES, a new request for confirmation is displayed
C: Delete old settings ? No
• Press the YES and ENTER button to confirm once more.
• You can control the brightness of the display or the angle at
which you have an optimal contrast by programming a value
between 1 and 20.
• The default value is 9.
• By pressing the ARROW LEFT or RIGHT button, you can
adjust the value. Press the ENTER button to confirm.
• If the machine functions with a frequency inverter controlled
motor, put the selection on YES.
• Press the ENTER button to confirm.
• For machines with frequency inverter controlled motor the
Full Wash Control Computer must know the applied Supply
Voltage of the washing machine.
• This value can be found at the machine data plate at the
back side of the washing machine.
• Make sure that you insert the correct Voltage Supply value
because otherwise the Mitsubishi Inverter will not function
properly.
• Confirm by pressing the ENTER button.
PROGRAMMING MANUAL
100962 G
PUBLICATION DATE 24 JUN 2008.DOC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents