THE SOAK SEQUENCE
Prewash
| Wash | Cooldown | Rinse | Final
P:Pr XX Step XX
Temp : 40 °C
P:Pr XX Step XX
Inlet : _ _ _ _
P:Pr XX Step XX
Level : _ _
100962 G
PUBLICATION DATE 24 JUN 2008.DOC
Soak
Rinse
|
°C : degrees Celsius
°F : degrees Fahrenheit
• The temperature can be programmed between 1°C and
45°C.
• 40°C is the suggested default value.
• Insert the desired temperature. Press the ENTER button for
confirmation.
Top Soap Hopper washing machines
• 4 Inlets can be programmed. I1, I2, I3, I4, I5 and I6 are
available.
• As for a default of 40°C, the suggested inlet valves are I2
and I3.
• The suggested inlet valves are related to the temperature
and the soap box.
• Insert the desired inlet valves. Press the ENTER button for
confirmation.
Front Soap Hopper washing machines
• 3 Inlets can be programmed. I1, I2, and I3 are available.
• For 40°C, the suggested inlet valves are I2 and I3.
• Insert the desired inlet valves. Press the ENTER button for
confirmation.
Attention !
!
If you insert other inlet valves than the suggested ones,
Problems can occur at the water fill process.
• The suggested Water Level corresponds with the Normal
Low water level.
• The suggested water level depends of the machine type.
• Check the corresponding table paragraph 3.4.
• The water level can only be programmed within certain limits.
• Insert the desired water level. Press the ENTER button for
confirmation.
PROGRAMMING MANUAL
|
Flush
| Spray | No wash