I:Language
English
English
| French | Spanish | German | Dutch | Czech | Polish | Finnish | Danish | Slovenian | Italian |
I:Service
Intervall : 9999
I:Buzzer
Time : 5 Sec
I:Allow
Advance : Yes
I:Automatic
Cooldown : Yes
100962 G
PUBLICATION DATE 24 JUN 2008.DOC
• Select the preferred Language from the list by pressing the
ARROW LEFT or RIGHT button.
• English is the default setting.
• Press the ENTER button to confirm.
• Insert the number of cycles at which a maintenance is
required. See Maintenance Manual.
• the default setting is :
- 9999 for machines with top soap dispenser.
- 3000 for machines with front soap dispenser.
• Press the ENTER button to confirm.
• Insert the buzzer time. At the End of the Wash cycle, when
the message Unload is displayed, the buzzer will function for
the programmed time.
• 5 Seconds is the default value.
• Press the ENTER button to confirm.
• The buzzer will function each time the attention of the
operator is needed.
• The programmable Buzzer time interval is not applicable in
the case of error messages.
• With the Advance function you can Skip a Sequence or
extend & decrease the time of a Sequence.
• Yes is the default value. (No for MB-machines)
• Yes : the Advance function is enabled.
No : the Advance function is disabled.
• Press the ENTER button to confirm.
• To avoid mechanical temperature shock and to extend
the life time of your washing machine, after a hot wash, cold
water is injected bit by bit. As a result at the end of the hot
wash, the temperature will be lowered to about 65°C.
• The automatic cool-down function will only be functional if a
hot wash with a temperature above 65°C has been
programmed and if a cold water inlet valve is programmed in
the next step. When a Cool-down sequence has been
programmed, the automatic cool-down will not function.
• The automatic cool-down differs from a normal cool-down
sequence. The purpose of a cool-down sequence is to
PROGRAMMING MANUAL
...