3 x 380 – 415 V + N
1 x 208 – 240 V | 3 x 208 – 240 V | TTL
C:Load Inverter
Parameters? Yes
C:Total N° of
Inlets: 2
2
| 3
100962 G
PUBLICATION DATE 24 JUN 2008.DOC
ATTENTION !!!
The Selection TTL is only for Mitsubishi inverters Type :
FR-A024-S0.4K - S2.2K-EC and FR-A044-0.4K - 3.7K-EC
For these inverters you don't have to select the Supply
Voltage of the washing machine.
You have to select the list element TTL.
From October 2000, these inverters have been replaced by
inverters from the E500 Series (Current ) that do NOT function
with TTL communication anymore.
| 1 x 220 – 240 V | 3 x 220 – 240 V | 3 x 380 – 480 V (N) |
Loading the Mitsubishi Frequency Inverter Parameters is an
advanced feature.
• These parameters ensure that the Inverter – Motor
combination will function properly on your washing
machine.
• Therefore you have to make sure that the Machine Type and
Voltage Supply corresponds with the data plate at the
backside of the machine.
• Confirm by pressing the ENTER button.
• As a result you will be asked if you are sure about your
selection. C: Delete old settings ? No
• Press the Yes and ENTER button to confirm once more.
• A washing machine can be delivered with 2 or 3 water inlet supplies.
• A machine with 2 water inlet supplies functions with:
- soft warm water
- soft cold water
• A machine with 3 water inlet supplies functions with:
- soft warm water
- soft cold water
- hard or recycled cold water
• Depending this selection other inlet valves will be suggested
at the final rinse sequence.
• Depending this selection other inlet valves will be
programmed when the standard programs are loaded.
• The number of inlets must be selected by the ARROW LEFT
or RIGHT button.
• Confirm by pressing the ENTER button.