I:Main Water
Pressure : High
I:Wait
Soap : No
100962 G
PUBLICATION DATE 24 JUN 2008.DOC
Attention !
!
It's strongly recommended that the heating power of the
steam installation has enough power to heat the bath
quickly. Otherwise the tub will be filled with extra water and
an error message will occur that the machine takes more
then 10 units extra water.
This will also increase the water, energy and supply
consumption.
To solve the problem in another way it is possible to reduce
the programmed target water level so that also less energy
is needed to heat up the bath and with the extra water you
will wash with a normal amount of water.
• Only for machines with Front Soap Hopper.
• If the main water supply pressure is low it can happen that
the plastic soap hoppers don't fall at the wash sequence.
In this case you must set the selection "Main Water
Pressure" : Medium or Low.
As a result the main water inlet will get closed before the
plastic soap hopper falls down.
(If High selected the main water inlet stays open.)
• Select "High, Medium or Low" from the list by pressing the
ARROW LEFT or RIGHT button.
• High is the default value.
• Confirm by pressing the ENTER button.
Remark :
The Setting is only applicable if "Hopper" is selected for
menu-item "Supply Signal A, B, C, D, E" in the Configuration
Menu.
Extra Info :
• Only applicable if a central soap dispensing unit is used for
multiple machines at the same time.
• When a machine receives liquid soap then the other
machines have to wait until the soap sequence is finished.
The machine that waits at it's liquid soap sequence receives
an On Hold Signal from the central soap dispensing unit.
While the machine is waiting, on the display appears the
message "Wait Soap".
When the On Hold Signal dissapears, then the machine
receives the liquid soap and continues the wash cycle.
• No is the default value.
• Yes : Wait for Soap enabled.
No : Wait for Soap disabled.
• Confirm by pressing the ENTER button.