7. PRE-PROGRAMMED PROGRAMS

The Full Control Wash Computer contains 15 pre-programmed Standard Wash Programs.
(Standard Programs : 1 to 15.
ATTENTION !!!
!
THE PRE-PROGRAMMED PROCESSES ARE GIVEN AS AN EXAMPLE ONLY.
FOR THE CREATION OF YOUR OWN WASH PROGRAM'S, CONTACT YOUR SOAP SUPPLIER.

7.1. LEGEND

SUPPLY TIMES
The water supply time for hopper A, B, C, D and E is default 30 seconds and can be adjusted in the
Program menu.
WATER INLETS (VALVES)
• Machines with TOP SOAP HOPPER
- Inlet Valve 1 :
- Inlet Valve 2 :
- Inlet Valve 3 :
- Inlet Valve 4 :
- Inlet Valve 5 :
- Inlet Valve 6 :
(*) If No Cold Hard water is available, then Inlet Valve 1 will function with Cold Soft Water.
• Machines with FRONT SOAP HOPPER
- Inlet Valve 1 :
- Inlet Valve 2 :
- Inlet Valve 3 :
WATER LEVEL
- NL: Normal Low level
- NH: Normal High level
WASH ACTION
• Normal Wash Action
- A = 12"
12 Seconds Action
- R = 3" 3 Seconds Rest
RPM (REVOLUTIONS PER MINUTE)
- W :
type R/F/X =
type RF/FF/XF/MB =
- D
:
type R =
type F/X =
type RF/FF/XF/MB =
- L
:
type R =
type F/X =
type RF/FF/XF/MB
- H
:
type R/RF =
type F/X =
type FF/XF/MB =
82
Programs 16 to 52 are dedicated.)
Cold Hard Water (*)
Cold Soft Water
Hot Soft Water
Hot Soft Water
Cold Soft Water
Cold Soft Water
Cold Hard water (Inlet Valve 1 is not operational, if no hard water is available)
Cold Soft water
Hot Soft water
• Gentle Wash Action
- A = 3" 3 Seconds Action
- R = 12"
Washing Speed (≈ 40 – 42 RPM)
Washing Speed (≈ 32 – 50 RPM)
Washing Speed (≈ 40 – 42 RPM)
Distribution Speed (≈ 100 RPM)
Distribution Speed (not changeable) (≈ 100 RPM)
Extraction speed (≈ 500 RPM)
Low extraction speed (≈ 500 RPM)
Low extraction speed, standard (≈ 500 RPM)
Extraction speed (≈ 500 RPM)
1 Minute Low (≈ 500 RPM)
+ rest high extraction speed (≈ 850 – 1000 RPM)
High extraction speed (≈ 625 – 1000 RPM)
(depending the size of the machine)
PROGRAMMING MANUAL
Soap Hopper "C"
Final Rinse
Soap Hopper „A"
Pre wash
Direct Inlet (Liquid)
Soap Hopper „B"
Main Wash
Soap Hopper „B"
Main Wash
Direct Inlet (Liquid)
12 Seconds Rest
100962 G
PUBLICATION DATE 24 JUN 2008.DOC