THE COOLDOWN SEQUENCE
Cooldown
Prewash
| Wash |
• After a Hot wash you can program a Cool-down Sequence to avoid the temperature shock and
shrinking of the garments.
• The drain step after the Hot wash must be put on NO DRAIN.
• No inlets are programmable for :
- the Top Soap hopper machines : inlet 6 is the standard inlet.
- the Front Soap hopper machines : inlet 2 is the standard inlet.
• The water level can't be programmed as the process of adding and draining water doesn't allow
this.
ATTENTION !
!
DO NOT PROGRAM A DRAIN SEQUENCE BEFORE A COOLDOWN SEQUENCE
P:Pr XX Step XX
Temp : 60 °C
P:Pr XX Step XX
RPM : _ _
P:Pr XX Step XX
Drain valve : 1
1
| 2 | 1+2
100962 G
PUBLICATION DATE 24 JUN 2008.DOC
| Rinse |
Final Rinse
| Soak |
°C : degrees Celsius
°F : degrees Fahrenheit
• The temperature can be programmed between 1°C and
60°C.
• 60°C is the suggested default value.
• Insert the desired temperature. Press the ENTER button for
confirmation.
• The suggested drum speed value depends of the machine
type.
• Check the corresponding table paragraph 3.4.
• The drum speed value can only be programmed within
certain limits.
• Insert the desired speed value. Press the ENTER button for
confirmation.
• Only available on washing machines with both : a normal
Open and a normal Closed Drain valve.
• As water will be drained at the Cool-down Sequence, it must
be possible to select the drain valve 1 or 2.
• The default Drain valve is Drain valve 1.
• Select the desired Drain Valve by pressing the
ARROW LEFT or RIGHT button.
• Press the ENTER button for confirmation.