3.4. PROGRAMMING THE FUNCTIONS

Limits
To ensure the correct functionality of the washing machine you have to program values within
certain limits.
If you program a value that falls below the minimal or above the maximal programmable limit
then the new value will not be accepted and the previous value stays valid.
Programming the Water Temperature
Limits
- Minimum value : 1 °C
- Maximum value : 45°C for the PREWASH and SOAK and 92°C for the WASH sequence.
- For RINSE, FINAL RINSE, FLUSH and SPRAY no Temperature can be programmed.
Programming the Inlet valves
Depending the programmed temperature the inlet valves are suggested.
While the tub is filling with water, the computer controls the water temperature. By switching on
and off the hot and cold water inlet valves the correct water temperature is obtained.
For machines with a Top Soap Hopper you have to consider that by programming the inlet
valves, at the same time, you are also selecting the soap Box at which the soap must be added.
If you want to program a wash sequence with :
- Cold Water :
- Warm or Hot water :
Top Soap Hopper washing machines :
The cold water inlet valves
Inlet Valve 2
Inlet Valve 5
Inlet Valve 1
Inlet Valve 6
The hot water inlet valves
Inlet Valve 4
Inlet Valve 3
How to select inlet valves : EXAMPLE
For a Prewash :
For a Wash :
For a Rinse :
For a Final Rinse : Inlet valve 1 (cold hard) (or cold soft)
100962 G
PUBLICATION DATE 24 JUN 2008.DOC
only Cold Inlet Valves must be programmed
Cold and Hot Inlet Valves must be programmed
corresponds with Soap Box A (Prewash)
corresponds with Soap Box B (Wash)
corresponds with Soap Box C (Final Rinse)
is a direct Inlet Valve and speeds up the water fill process
corresponds with Soap Box B (Wash)
is a direct inlet Valve and speeds up the water fill process
Programmable temperature:
Inlet Valve 2 (cold)
+ Inlet Valve 3 (hot) and/or 6 (cold)
Programmable temperature:
Inlet Valve 4 (hot) and/or 5 (cold)
+ Inlet Valve 3 (hot) and/or 6 (cold)
Inlet valves 2 + 5 + 6 (cold)
+ Inlet valve 6 (cold soft)
MFR
1 - 45°C
Soap box A
Direct Inlets
1 - 92°C
Soap box B
Direct Inlets
No Soap is added
Soap box C
only if No cold hard water for Inlet 1
PROGRAMMING MANUAL