P:Pr XX Step XX
Supply A: 0 Sec
P:Soap Supply
Menu
Exit
P:Pr XX Step XX
On Time : _ _ Sec
P:Pr XX Step XX
Off Time : _ _ Sec
P:Pr XX Step XX
Time : 2.0 Min
54
• Liquid soap supplies can only be programmed if the selection
in the configuration menu is enabled.
• The supplies can be programmed for an interval time
between 0 and 99 seconds.
• The supply will not be activated if 0 Seconds is programmed.
• Up to 4 supplies can function at the same time at the same
Sequence.
If you have programmed more then 4 supplies an error
message will be generated. Put the time of the supplies back
to zero until not more than 4 non-zero time values are
remaining.
• The overview display shows the Supply Name and the
corresponding programmed time.
• Insert the desired supply time. Press the ENTER button for
confirmation.
• At the end of the Menu, when EXIT is displayed,
press the ENTER button to leave the supply Menu.
Attention !
!
For Front Soap Hopper washing machines, the soap is
added by programming the supplies A to E. (X22/5 A to D)
External liquid soap pumps correspond with the supplies
F to K.
For Top Soap Hopper washing machines, the External liquid
Soap pumps correspond with the supplies D to N.
The number of external supplies that is available depends
on the machine type.
• The wash motor ON time can be programmed between 0 and
99 seconds.
• The wash motor OFF time can be programmed between 3
and 99 seconds.
• The suggested default values can be adapted in the
Initialisation menu.
• Standard wash motor ON time of 12 seconds and a wash
motor OFF time of 3 seconds is recommended for normal
wash. A wash motor ON time of 3 seconds and a wash motor
OFF time of 12 seconds is recommended for a gentle wash
(woolens).
• Insert the desired ON – OFF times. Press the ENTER button
for confirmation.
• FS120, MB90, MB140, MB180 : 12Sec ON and 5Sec OFF
• The Rinse Sequence can be programmed between 0 and
99 minutes in steps of 0.5 minutes.
• The default time is 2.0 Minutes.
PROGRAMMING MANUAL
100962 G
PUBLICATION DATE 24 JUN 2008.DOC