DIAGNOSE:
1. Check if the input connector A is connected
2. Check the functioning of the
"DOOR SOLENOID SWITCH"
3. Check the door lock coil
4. Check the mechanical functionality of the
door lock
5. Check the continuity of the wiring
6. Check the output relay that powers the door
lock coil
7. Check the output relay that powers the door
lock coil
8. Check the functioning of the „DOOR
SWITCH"
9. Check the well functioning of RL20
FAILURE 9: DOOR SOLENOID SWITCH CLOSED FAILURE
If within 30 sec the "DOOR SOLENOID SWITCH" doesn't change state at the end of the cycle:
Message 9 will be displayed. At the end of the cycle the Door Lock coil is switched off and the "DOOR
SOLENOID SWITCH" must open it's contact. If the contact is broken and stay closed forever, the software
will give a message to inform the user that the door lock system isn't safe anymore.
DIAGNOSE:
1. Check the functioning of the "DOOR
SOLENOID SWITCH"
2. Check the door lock coil
3. Check the mechanical functionality of
the door lock
4. Check the continuity of the wiring
5. Check the output relay that powers
the door lock coil
6. Check the output relay that powers the door
lock coil.
FAILURE 10: BIMETAL/SPRING
The bimetal/Spring is an extra security that the door can not be opened immediately when the power is
switched off. To verify that the bimetal/Spring is not defective, the bimetal/Spring is checked each cycle. If the
bimetal/Spring is defective : at the end of the program, failure message 10 is displayed.
DIAGNOSE:
1. Check the bimetal/Spring
2. Check the mechanical functionality of the
door lock.
3. Check the continuity of the wiring
108
If the input connector A is not connected : connect
connector A
If the door switch is broken or functions not 100% :
replace the door lock system
If the door lock coil doesn't function : replace the door
lock coil
If the door lock is not functioning mechanically :
replace the door lock system
If the wiring is not continuous : repair the wiring
If the relay is broken, replace the electronic board
If the relay is not broken, but doesn't receive a signal
from the electronic board, replace the electronic board
If the door switch is broken or functions not 100% :
replace the door lock system
If RL20 is not well functioning replace the electronic
board.
If the door switch is broken or functions not 100%:
replace the door lock system
If the door lock coil doesn't function: replace the door
lock coil
If the door lock is not functioning mechanically: replace
the door lock system
If the wiring is not continuous: repair the wiring
If the relay stays closed and the relay is broken,
replace the electronic board
If the relay is not broken, but receives a not allowed signal
from the electronic board, replace the electronic board
If the bimetal/Spring is defective: replace the
bimetal/Spring
If the door lock is not functioning mechanically:
replace the door lock system
If the wiring is not continuous: repair the wiring
PROGRAMMING MANUAL
100962 G
PUBLICATION DATE 24 JUN 2008.DOC