6.20. OPEN SOAP BOX

ONLY FOR WASHING MACHINES WITH FRONT SOAP BOX
By opening the soap box, the Program is interrupted at once.
First the machine will go over to a safe state.
Then the message CLOSE SOAP DOOR is displayed.
Once the soap box is closed again, the message CONTINUE ? will be displayed.
STOP : the program is stopped. (A tumble sequence will be executed before the door can be opened.)
START : the program restarts the last active step, and goes on with rest of the program.
It's recommended to program a pause (signal) if you want to fill the same soap hopper twice while
the program is running.

6.21. WAIT STATE

It can occur that the normal machine operation has been interrupted and that you have to wait until
the Full Control Wash Computer allows you to go on.
You can recognize the wait state by a display that shows WAIT and a decreasing counter.
This will occur when the power has been switched off and on at a running wash cycle.
As the software doesn't know how fast the motor was spinning, a delay time is respected before
the machine can be restarted.

6.22. HOW TO HANDLE FAILURE MESSAGES

When a failure has been detected by the Full Control Wash Computer, a failure message is
generated, to inform the operator about the problem.
PrAA StBB Unload !
EXXX:YYYYYYYYYYYY
AA
: The Program number
BB
: The Step number
Unload !
: If it is allowed to open the door, the message Unload is displayed
E XXX
: The error number
YYYYYYYY : The name of the error message
At the upper left corner, the program number and step number of the interrupted program are
displayed.
The message UNLOAD ! will inform you if it's allowed to open the door.
Safety conditions
If there is still water in the drum or if the temperature is too high, it's not possible to open the door.
The messages „WATER IN CAGE" or „TOO HOT" will be displayed together with the level and the
temperature.