THE STATIC DRAIN SEQUENCE
Drain | Extract |
Low Extract
The drum is at standstill while the water is drained.
P:Pr XX Step XX
Drain valve : 1
1
| 2 | 1+2
P:Pr XX Step XX
Time : 0,5 Min
P: Program
Step XX
Exit
Attention !!!
!
It's not recommended to program a spin sequence just after a Static Drain Sequence.
At a Static Drain sequence, the garments are not distributed around the drum while the water is drained.
When the spin sequence starts, the garments are a big imbalance and the imbalance (tilt) function will be
activated.
100962 G
PUBLICATION DATE 24 JUN 2008.DOC
|
High Extract
| No Drain |
• Only available on washing machines with both : a normal
Open and a normal Closed Drain valve.
• You can select Drain Valve 1 or 2.
• The default Drain valve is Drain valve 1.
• You have to select the desired Drain Valve by pressing the
ARROW LEFT or RIGHT button.
• Press the ENTER button for confirmation.
• The Drain Sequence can be programmed between 0 and 9,5
minutes in steps of 0,5 minutes.
• The default time is 0,5 Minutes.
• Programming a time of 0 minutes : the Drain part will not be
functional (cfr No Drain)
• Insert the desired Drain sequence time. Press the ENTER
button for confirmation.
• You can always return to a previous menu item by pressing
the ARROW UP button.
• By pressing the ENTER button you will leave the current
Step. Goto