I:Max. Heating
Time : 60 Min
I:Max. WaterFill
Time : 10 Min
I:Max. level
Overfill : 10
26
and a stable water temperature is obtained. If the
programmed water temperature is not reached within 30
seconds, the heating will be started again.
• The default value is 0%. (The function is switched Off)
• A value between 0% and 30% can be programmed.
• Press the ENTER button to confirm.
• The Full Control wash computer will generate a diagnostic
message when the water hasn't reached the programmed
temperature in 60 Minutes.
• 60 Minutes is the default value.
• Some operators want to adjust this time. A value between
10 and 99 minutes can be selected.
• Press the ENTER button to confirm.
Attention !
!
If 99 minutes has been selected, NO error message will be
generated at all, even if the heating time exceeds 99
minutes.
The machine will only stop heating when the programmed
temperature has been reached.
• The Full Control wash computer will generate a diagnostic
message when the water hasn't reached the programmed
level in 10 Minutes.
• 10 Minutes is the default value. (15 Minutes F120)
• Some operators want to adjust this time. A value between
5 and 99 minutes can be selected.
• Press the ENTER button to confirm.
Attention !
!
If 99 minutes has been selected, NO error message will be
generated at all, even if the fill time exceeds 99 minutes.
The machine will only stop filling when the programmed
water level has been reached.
• The Full Control wash computer will generate a diagnostic
message when the water has reached the programmed
level + 10 units.
• 10 units is the default value.
• Some operators want to adjust this alarm level. A value
between 10 and 25 units can be selected.
• Press the ENTER button to confirm.