6.15. FLUSH FUNCTION

Only for machines with a Top Soap Hopper.
At the Fill process of the Flush sequence, No water level is programmed and the water will escape
by the overflow hole.
The larger soil particles will get separated from the garments due to the water that is draining
through the overflow hole.

6.16. SPRAY FUNCTION

For machines with a Spray inlet.
The spray function can be programmed instead of a rinse.
Water will be injected by the spray-head in the door glass.
The drain valve is open and depending the programmed speed, the drum will spin at distribution or
low spin speed.
For special applications.
Instead of injecting water by the spray head at the door glass, it's also possible to program a
supply.
The product will be injected while the drain valve is open and depending the programmed speed,
the drum will spin at distribution or low spin speed.

6.17. UNBALANCE

When the machine is badly loaded during the spin sequence, then the tilt switch will get activated.
The spin sequence will be interrupted and the garments in the drum will be redistributed.
The washing machine will try up to 10 times to redistribute the laundry.

6.18. PAUSE

When a signal has been programmed, at the end of a wash sequence, the machine will stop the
Program and the message CONTINUE? will be displayed.
The buzzer will give a warning for the operator.
Now the operator can add Soap.
By opening the Soap Door, the buzzer is switched off.
(Only for Front Soap Hopper Washing Machines)
By pressing the START button the PROGRAM will go on with the next Program step.

6.19. STOP

By pressing the STOP button the program is interrupted.
First the machine will go over to a safe state.
Then the message CONTINUE ? is displayed.
STOP : the program is stopped. (A tumble sequence will be executed before the door can be opened.)
START : the program restarts the last active step, and goes on with the rest of the program.
100962 G