Programming the Motor On and Off times for Reversing
The standard Reversing Motor On and Off times at Wash speed are 12 Seconds On and 3 Seconds Off.
For Delicates and Woolens it's recommended to program a gentle wash action with a
Reversing On time of 3 Seconds and an Off time of 12 Seconds.
Programming the Sequence time.
The sequence time starts running after the water level is reached.
If wait for Temperature has been selected, the sequence time starts only running once the
programmed temperature has been reached at the heating process.
For a Cooldown Sequence, the programmed time corresponds with the time for decreasing the
water temperature.
Recommendation :
At least a cooldown of 3 minutes must be programmed. And to avoid the shrinking of the garments,
it's recommended to program the time so that the temperature will decrease with about 3°C for each
minute.
ATTENTION !!!
!
FOR A SPRAY SEQUENCE, IF A SUPPLY HAS BEEN PROGRAMMED, THE SEQUENCE TIME
CORRESPONDS WITH THE PROGRAMMED SUPPLY TIME.
Signal
The signal should be programmed when a running wash cycle has to be interrupted.
The Buzzer will be activated, to alert the operator.
For most cases, the operator interrupts a program to fill the soap hopper an additional time.
The program interruption will always occur at the end of a step.
Programming water recycling Inlets and Outlets
Only FS120 & MB machines
Optional feature for which the electrical and water installation in and outside the washing machine
must be extended.
• Case 1
If in the Configuration menu "Drain Valve 2 : Yes" & "Recycling Inlets : Yes" is selected, it's
possible to program 3 extra water inlets in the wash sequences and 3 extra water outlets
in the drain-extraction sequences.
In the wash sequences it's possible to program 3 extra water supply inlets : 4, 5, 6 dedicated
for water recycling. These water inlet valves will function as cold water inlet valves for
respectively recycle tanks 1, 2, 3.
In the drain-extraction sequences it's possible to program 3 extra outlet valves dedicated for
water recycling. Select drain valve 1 if the water must be drained to the sewer and drain valve
2 in combination with outlet valves (selection drain valve : 2>1, 2>2, 2>3) if the water must be
pumped to the water recycling tanks respectively tank 1, 2 and 3.
• Case 2
If in the Configuration menu "Drain Valve 2 : Yes" & "Recycling Inlets : No" is selected, it's
possible to select a second drain valve for water recycling in the drain-extraction sequences.
Select drain valve 1 if the water must be drained to the sewer and drain valve 2 if the water
must be pumped to the water recycling tank.
Water supply Inlet 1 can function as water recycle inlet valve. (Replaces the hard water supply).