P:Pr XX Step XX
Time : 2.0 Min
P:Pr XX Step XX
Signal : No
58
• The Final Rinse Sequence can be programmed between 0
and 99 minutes in steps of 0.5 minutes.
• The default time is 2.0 Minutes.
• Programming a time of 0 minutes : the Final Rinse will not be
functional (cfr No Wash)
• Insert the desired Final Rinse time. Press the ENTER button
for confirmation.
• When a signal is programmed, a pause will be introduced at
the end of the Wash Step. This allows the operator to add
soap for the next step. To alert the operator that the program
has been interrupted, a buzzer signal will be activated.
By pressing the START button, the program will continue.
• Yes : Signal enabled.
No : Signal disabled.
• Press the ENTER button for confirmation.