THE HIGH EXTRACT SEQUENCE
Drain | Extract |
Low Extract
Only for washing machines with 2 motors.
P:Pr XX Step XX
Drain valve : 1
1
| 2 | 1+2
P:Pr XX Step XX
Time : 4,5 Min
P: Program
Step XX
Exit
THE NO DRAIN SEQUENCE
Drain | Extract |
Low Extract
• The Drain/Extraction part of the programmed step is skipped.
Attention !!!
!
For some specific functions "No Drain" must be programmed.
Example:
If you want to program a Cool-down Sequence, then "No Drain" must be programmed between the Hot Wash
and the Cool-down Sequence.
P: Program
Step XX
Exit
70
High Extract
|
| No Drain | Static Drain
• Only available on washing machines with both : a normal
Open and a normal Closed Drain valve.
• You can select Drain Valve 1 or 2.
• The default Drain valve is Drain valve 1.
• You have to select the desired a Drain Valve by pressing the
ARROW LEFT or RIGHT button.
• Press the ENTER button for confirmation.
• The High Extract Sequence can be programmed between 0
and 9.5 minutes in steps of 0.5 minutes.
• The default time is 4.5 Minutes.
• Programming a time of 0 minutes : the High Extract step will
not be functional (cfr No Drain)
• Insert the desired High Extract sequence time.
Press the ENTER button for confirmation.
• You can always return to a previous menu item by pressing
the ARROW UP button.
• By pressing the ENTER button you will leave the current
Step. Goto
No Drain
|
High Extract
|
• You can always return to a previous menu item by pressing
the ARROW UP button.
• By pressing the ENTER button you will leave the current
Step. Goto